Sea Recovery Ultra Whisper Rev. A
Low Pressure Abnormality 1.
SYSTEM SHUTS DOWN DURING OPERATION OR 20 SECONDS AFTER
STARTING AND THE HIGH/LOW PRESSURE FAULT LAMP IS ILLUMINATED
AFTER SHUTTING DOWN.
Properly Position Valves
a) Ensure that the Sea Cock Valve [2] is fully open.
b) Ensure that the Inlet Rinse Clean Valve [36], if installed, is positioned towards the Sea Strainer [4]
normal operating position.
a. POSSIBLE CAUSE: BLOCKAGE IN THE SUCTION LINE.
1) Press Reset Fault Switch to reset and turn off the “High/Low Pressure” Fault Lamp.
2). Start the System
IF The Feed Pump Inlet Compound Vacuum/Pressure Gauge [5] registers a heavy Vacuum reading greater than
-10 In Hg as illustrated below which indicates there is a blockage at or prior to the Inlet of the Feed Pump
[6]. Correct the condition as described below: The System will shut down when the blockage in the suction
line causes the Prefilter Inlet Pressure Gauge [12] to drop below 40 PSI.
50
100
150
200
250
300
0
PSI
PSI
1400
1200
1000
800
600
400
200
0
PSI
0
300
250
200
150
100
50
IN HG
PSI
70
60
50
40
30
20
10
-30
0
[5]
FEED PUMP INLET
COMPOUND
VACUUM / PRESSURE
-30 - 0 - 60 PSI
[12]
PREFILTER INLET
PRESSURE GAUGE
0 - 300 PSI
[16]
PREFILTER OUTLET
ETD INLET
PRESSURE GAUGE
0 - 300 PSI
[18]
OPERATING PRESSURE
DEVELOPED BY THE ETD
0 - 1500 PSI
1). Clean or replace the Sea Strainer [4] mesh screen.
2). Clean debris attached to or sucked up within the Inlet Thru Hull Fitting [1] (plastic bag, cloth rag, sea
weed, marine growth, fitting installation caulking, new boat shipping cover or tape, casting slag over
the opening, etc.).
section 6 page 7 of 38
Содержание SRC Ultra Whisper Compact 200
Страница 2: ......
Страница 3: ...Ultra Whisper 200 600 Owner s Manual ...
Страница 5: ...This page is intentionally blank ...
Страница 11: ...Sea Recovery Ultra Whisper Rev A vi ...
Страница 12: ...Sea Recovery Ultra Whisper Rev A vii ...
Страница 14: ...Sea Recovery Ultra Whisper Rev A ix ...
Страница 108: ...Sea Recovery Ultra Whisper Rev A Section 3 New System First Time Start Up Commissioning Section 3 Page 1 of 12 ...
Страница 120: ...Sea Recovery Ultra Whisper Rev A Section 4 Daily Operation Instructions Section 4 Page 1 of 12 ...
Страница 132: ...Sea Recovery Ultra Whisper Rev A Section 5 System Storage R O Membrane Element Cleaning section 5 page 1 of 16 ...
Страница 148: ...Sea Recovery Ultra Whisper Rev A Section 6 Troubleshooting of Abnormalities section 6 page 1 of 38 ...
Страница 186: ...Sea Recovery Ultra Whisper Rev A Section 7 Maintenance Repair section 7 page 1 of 39 ...
Страница 225: ...This page is intentionally blank ...
Страница 245: ...Sea Recovery Ultra Whisper Rev A Δ B00738000X FEED WATER PUMP ASSEMBLY ULTRA WHISPER 200 600 section 9 page 8 of 49 ...
Страница 251: ...Sea Recovery Ultra Whisper Rev July 2008 section 9 page 14 of 49 ...
Страница 259: ...FRESH WATER FLUSH ASSY B598000005 Illustration 20 3 22 13 12 11 8 1 4 23 25 26 15 10 6 28 24 7 17 9 5 21 18 2 27 14 19 ...
Страница 290: ...Sea Recovery Ultra Whisper Rev A SECTION 10 CONVERSION CHARTS INFORMATION TABLES section 10 page 1 of 8 ...
Страница 298: ......