![Sea Recovery SRC Ultra Whisper Compact 200 Скачать руководство пользователя страница 174](http://html1.mh-extra.com/html/sea-recovery/src-ultra-whisper-compact-200/src-ultra-whisper-compact-200_owners-manual_1221262174.webp)
Sea Recovery Ultra Whisper Rev. A
Abnormality 2.
SYSTEM PRODUCTION, PRODUCT WATER FLOW, IS HIGHER THAN
NORMAL.
The Ultra Whisper System self adjusts the operating pressure, up or down accordingly, to produce the specified
amount of Product Water. Therefore, the System should never produce more Product Water than specified unless
one or more of the following has occurred:
a. There is a blockage in the Brine Discharge Line causing Brine Water by-pass into the Product Water
b. The 3-way Product Water Diversion Solenoid Valve is not properly adjusted
c. There is bypassing of the Feed Water into the Product Water due to a broken or worn Product Water O-
ring, a crack or imperfection in the High Pressure Vessel End Plug, or the R.O. Membrane Element is
damaged.
d. The System components have been mismatched
IF The Feed Pump Inlet Compound Vacuum/Pressure Gauge [5] registers Normal with slight vacuum or 0 (zero)
PSI, and the other 3 pressure gauges (Prefilter Inlet Pressure Gauge [12], Prefilter Outlet Pressure Gauge
[16], and Operating Pressure Gauge [18]) all register higher than normal this would indicate that there could
be a blockage in the Brine Discharge Line causing the excessive pressure readings and by-passing of Brine
Water into the Product Water through the 3-way Product Water Solenoid Diversion Valve resulting in excess
Product Water Flow.
50
100
150
200
250
300
0
PSI
PSI
1400
1200
1000
800
600
400
200
0
PSI
0
300
250
200
150
100
50
IN HG
PSI
70
60
50
40
30
20
10
-30
0
[5]
FEED PUMP INLET
COMPOUND
VACUUM / PRESSURE
-30 - 0 - 60 PSI
[12]
PREFILTER INLET
PRESSURE GAUGE
0 - 300 PSI
[16]
PREFILTER OUTLET
ETD INLET
PRESSURE GAUGE
0 - 300 PSI
[18]
OPERATING PRESSURE
DEVELOPED BY THE ETD
0 - 1500 PSI
a. POSSIBLE CAUSE: BLOCKAGE IN THE BRINE DISCHARGE LINE
2) Ensure that any valve in the Brine Discharge Line or at the Thru Hull Discharge Fitting [22] is full
OPEN.
3) Ensure that there are no kinks or other blockages in the Brine Discharge Line.
section 6 page 27 of 38
Содержание SRC Ultra Whisper Compact 200
Страница 2: ......
Страница 3: ...Ultra Whisper 200 600 Owner s Manual ...
Страница 5: ...This page is intentionally blank ...
Страница 11: ...Sea Recovery Ultra Whisper Rev A vi ...
Страница 12: ...Sea Recovery Ultra Whisper Rev A vii ...
Страница 14: ...Sea Recovery Ultra Whisper Rev A ix ...
Страница 108: ...Sea Recovery Ultra Whisper Rev A Section 3 New System First Time Start Up Commissioning Section 3 Page 1 of 12 ...
Страница 120: ...Sea Recovery Ultra Whisper Rev A Section 4 Daily Operation Instructions Section 4 Page 1 of 12 ...
Страница 132: ...Sea Recovery Ultra Whisper Rev A Section 5 System Storage R O Membrane Element Cleaning section 5 page 1 of 16 ...
Страница 148: ...Sea Recovery Ultra Whisper Rev A Section 6 Troubleshooting of Abnormalities section 6 page 1 of 38 ...
Страница 186: ...Sea Recovery Ultra Whisper Rev A Section 7 Maintenance Repair section 7 page 1 of 39 ...
Страница 225: ...This page is intentionally blank ...
Страница 245: ...Sea Recovery Ultra Whisper Rev A Δ B00738000X FEED WATER PUMP ASSEMBLY ULTRA WHISPER 200 600 section 9 page 8 of 49 ...