Feed Pump Maintenance and Repair
NOTE!
THIS SECTION APPLIES TO SYSTEMS WITH A TRIPLEX PUMP ONLY.
FAILURE SIGNS AND POSSIBLE CAUSES
1.
Pulsations at the Feed Gauge are caused by (check low pressure gauge for pulsations):
•
Worn or broken Valve
•
Worn or broken Valve Spring
•
Worn or broken Valve Seat
•
Debris in Valve Chamber
2.
Water Leak between the Feed Pump Manifold and Rear Section caused by:
•
Worn Seals or Seals damaged due to running dry.
3.
Flow drops dramatically when attempting to pressurize and there is no flow at the Product Flow Meter.
This is caused by:
•
Worn Seals
•
Seals damaged due to running dry
•
Broken Valve
•
Broken Valve Spring
•
Debris in Valve Chamber
FEED PUMP SERVICING
A. Disassembly of the Discharge Valve Assemblies:
Tools required:
3/8” Drive Ratchet; 6 mm Hex Socket; O-Ring Pick; Two slotted screwdrivers, Torque Wrench;
Needle Noise Pliers.
1.
Only one valve kit is required to repair all of the valves in one pump. The Valve Kit includes new valve O-
Rings, valve seats, valves, and springs.
2.
Disconnect all plumbing.
3.
Remove the six socket head screws from the manifold. Remove the outer screws first, then the inner
screws.
4.
Using a soft mallet, tap the back side of the Discharge Manifold from alternate sides to maintain
alignment and avoid damage to the plungers
5.
Grasp the Discharge Manifold from the underside and gradually lift manifold while you pull away from
the Crankcase.
6.
The Adapter/Spacers may stay with either the Discharge or Inlet Manifold. By inserting two opposing
screwdrivers between Spacer and manifold, you can easily pry them out of the Discharge Manifold. If
they stay in the Inlet Manifold, gently work them up and down as you pull away from the Inlet Manifold.
7.
The Valve Assemblies are in the Discharge Manifold ports and will fall out when manifold is turned over.
A complete valve assembly includes: Retainer, Spring, Valve and Seat.
section 7 page 5 of 39
Содержание SRC Ultra Whisper Compact 200
Страница 2: ......
Страница 3: ...Ultra Whisper 200 600 Owner s Manual ...
Страница 5: ...This page is intentionally blank ...
Страница 11: ...Sea Recovery Ultra Whisper Rev A vi ...
Страница 12: ...Sea Recovery Ultra Whisper Rev A vii ...
Страница 14: ...Sea Recovery Ultra Whisper Rev A ix ...
Страница 108: ...Sea Recovery Ultra Whisper Rev A Section 3 New System First Time Start Up Commissioning Section 3 Page 1 of 12 ...
Страница 120: ...Sea Recovery Ultra Whisper Rev A Section 4 Daily Operation Instructions Section 4 Page 1 of 12 ...
Страница 132: ...Sea Recovery Ultra Whisper Rev A Section 5 System Storage R O Membrane Element Cleaning section 5 page 1 of 16 ...
Страница 148: ...Sea Recovery Ultra Whisper Rev A Section 6 Troubleshooting of Abnormalities section 6 page 1 of 38 ...
Страница 186: ...Sea Recovery Ultra Whisper Rev A Section 7 Maintenance Repair section 7 page 1 of 39 ...
Страница 225: ...This page is intentionally blank ...
Страница 245: ...Sea Recovery Ultra Whisper Rev A Δ B00738000X FEED WATER PUMP ASSEMBLY ULTRA WHISPER 200 600 section 9 page 8 of 49 ...
Страница 251: ...Sea Recovery Ultra Whisper Rev July 2008 section 9 page 14 of 49 ...
Страница 259: ...FRESH WATER FLUSH ASSY B598000005 Illustration 20 3 22 13 12 11 8 1 4 23 25 26 15 10 6 28 24 7 17 9 5 21 18 2 27 14 19 ...
Страница 290: ...Sea Recovery Ultra Whisper Rev A SECTION 10 CONVERSION CHARTS INFORMATION TABLES section 10 page 1 of 8 ...
Страница 298: ......
Страница 299: ......