Abnormality 1.
SYSTEM PRODUCTION, PRODUCT WATER FLOW, IS LOWER THAN NORMAL.
Properly Position Valves
a) Ensure that the Sea Cock Valve [2] is fully open.
b) Ensure that the Inlet Rinse Clean Valve [36], if installed, is positioned towards the Sea Strainer [4]
normal operating position.
c) Ensure that the Discharge Rinse Clean Valve [37], if installed, is positioned towards the Brine Discharge
Connection [22] normal operating position.
d) Ensure that any valve in the Brine Discharge Line or at the Thru Hull Discharge Fitting [22] is full
OPEN.
e) Ensure that any valve in the Product Water Line is full OPEN.
f) Ensure that there are no kinks or other blockages in the Brine Discharge Line and or the Product Water
Line.
a. POSSIBLE CAUSE: BLOCKAGE IN THE SUCTION LINE.
1) If the “High/Low Pressure” Fault Lamp is illuminated, Press Reset Fault Switch.
2). Start the System
IF The Feed Pump Inlet Compound Vacuum/Pressure Gauge [5] registers a heavy Vacuum reading greater than
-10 In Hg as illustrated below which indicates there is a blockage at or prior to the Inlet of the Feed Pump
[6]. This will cause low Feed Water flow and in turn low Product Water flow. Correct the condition as
described below: The System will shut down when the blockage in the suction line causes the Prefilter Inlet
Pressure Gauge [12] to drop below 40 PSI.
50
100
150
200
250
300
0
PSI
PSI
1400
1200
1000
800
600
400
200
0
PSI
0
300
250
200
150
100
50
IN HG
PSI
70
60
50
40
30
20
10
-30
0
[5]
FEED PUMP INLET
COMPOUND
VACUUM / PRESSURE
-30 - 0 - 60 PSI
[12]
PREFILTER INLET
PRESSURE GAUGE
0 - 300 PSI
[16]
PREFILTER OUTLET
ETD INLET
PRESSURE GAUGE
0 - 300 PSI
[18]
OPERATING PRESSURE
DEVELOPED BY THE ETD
0 - 1500 PSI
1). Clean or replace the Sea Strainer [4] mesh screen.
2). Clean debris attached to or sucked up within the Inlet Thru Hull Fitting [1] (plastic bag, cloth rag, sea
weed, marine growth, fitting installation caulking, new boat shipping cover or tape, casting slag over
the opening, etc.).
section 6 page 22 of 38
Содержание SRC Ultra Whisper Compact 200
Страница 2: ......
Страница 3: ...Ultra Whisper 200 600 Owner s Manual ...
Страница 5: ...This page is intentionally blank ...
Страница 11: ...Sea Recovery Ultra Whisper Rev A vi ...
Страница 12: ...Sea Recovery Ultra Whisper Rev A vii ...
Страница 14: ...Sea Recovery Ultra Whisper Rev A ix ...
Страница 108: ...Sea Recovery Ultra Whisper Rev A Section 3 New System First Time Start Up Commissioning Section 3 Page 1 of 12 ...
Страница 120: ...Sea Recovery Ultra Whisper Rev A Section 4 Daily Operation Instructions Section 4 Page 1 of 12 ...
Страница 132: ...Sea Recovery Ultra Whisper Rev A Section 5 System Storage R O Membrane Element Cleaning section 5 page 1 of 16 ...
Страница 148: ...Sea Recovery Ultra Whisper Rev A Section 6 Troubleshooting of Abnormalities section 6 page 1 of 38 ...
Страница 186: ...Sea Recovery Ultra Whisper Rev A Section 7 Maintenance Repair section 7 page 1 of 39 ...
Страница 225: ...This page is intentionally blank ...
Страница 245: ...Sea Recovery Ultra Whisper Rev A Δ B00738000X FEED WATER PUMP ASSEMBLY ULTRA WHISPER 200 600 section 9 page 8 of 49 ...
Страница 251: ...Sea Recovery Ultra Whisper Rev July 2008 section 9 page 14 of 49 ...
Страница 259: ...FRESH WATER FLUSH ASSY B598000005 Illustration 20 3 22 13 12 11 8 1 4 23 25 26 15 10 6 28 24 7 17 9 5 21 18 2 27 14 19 ...
Страница 290: ...Sea Recovery Ultra Whisper Rev A SECTION 10 CONVERSION CHARTS INFORMATION TABLES section 10 page 1 of 8 ...
Страница 298: ......
Страница 299: ......