Operation & Maintenance Manual
──
LG946L Wheel Loader
13
z
Tighten all fuel and oil tank caps firmly.
z
Put the above flammable liquids in containers with relevant tags and put in a separate,
proper place for storage. Do not allow unauthorized people to use.
z
Electric welding and flame cutting is not allowed for the tubes containing flammable fluid.
Clean the tubes with nonflammable fluid before electric welding and flame cutting.
z
Clean thoroughly the flammable materials such as sawdust, leaves and paper which collect
in the engine and brake clip, and clean the flammable oil, lubricating oil and other
substances on the machine.
z
While operating, pay attention when the outlet of the muffler is close to flammable materials
such as withered grass and old papers.
z
When parking the loader, carefully select the environment; especially select the places where
there are no flammable materials near the parts with a high temperature such as the muffler.
z
Check whether there is the leakage of fuel, lubricating oil, or hydraulic oil. If so, repair or
replace the broken items. Clean the repaired items
before use.
z
If there is explosive air generated near the storage
battery, be sure there is no flame or fire nearby.
Repair, maintain and use the storage battery as
referenced in users manual.
z
Do not use flame or fire (match or lighter) to check
in a dark place.
z
The fire extinguisher should be ready for use at all
times and the user must be knowledgable about its use and function. Check and maintain it
as referenced in users manual.
z
Never operate machine near flame or fire.
z
Do not short circuit.
3.5 Precautions When Operating at High Temperature
z
Just after turning off the engine, the coolant, engine oil and hydraulic oil are at high
temperature and still under high pressure. The attempt to remove the cap, drain the oil or
water, or replace filters may lead to serious burns.
Always
wait for the temperature to go down, and
follow the specified procedures when performing
these operations.
z
Stop the engine, wait for the water to become cool,
and then loosen the cap slowly to relieve the inner