background image

Page 37 of 44

P/N 595189-01  Rev A  4/10

WArning

reSPirATorS muST be Thoroughly dry 

before And during STorAge. moiSTure 

on  A  reSPirATor  in  beloW  freeZing 

TemPerATureS mAy cAuSe A mAlfunc-

Tion  of  The  reSPirATor  Which  could 

reSulT in SeriouS inJury or deATh.

WArning

The Self-conTAined Air SuPPly cylin-

derS muST be filled WiTh comPreSSed 

Air  Which  meeTS  The  reQuiremenTS 

for  grAde  d  or  higher  comPreSSed 

Air  AS  SPecified  in  The  comPreSSed 

gAS  ASSociATion  PublicATion  cgA 

g-7.1.  in  AddiTion  To  meeTing  The  re-

QuiremenTS  of  grAde  d  or  higher, 

The Air muST be dry To A deW PoinT of 

-65°  f  /  -54°  c  or  leSS.  fAilure  To  fill 

The  cylinder  WiTh  breAThing  Air  AS 

SPecified mAy cAuSe A mAlfuncTion of 

The  reSPirATor  Which  could  reSulT 

in SeriouS inJury or deATh.

WArning

The  noSe  cuP  ASSembly  iS  reQuired 

for  uSe  of  ThiS  reSPirATor  in  Tem-

PerATureS AT or beloW freeZing, 32° 

f / 0° c. fAilure To uSe  The noSe cuP  

mAy  cAuSe  obScured  viSion  And/or 

PArTiAl  or  comPleTe  blocKAge  of 

The  AirfloW  Which  could  reSulT  in 

SeriouS inJury or deATh.

loW TemPerATure oPerATion 

The respirator is NIOSH approved for use in temperatures to -25°F / 

-32° C. For temperatures below +32° F / 0° C, approval requires use 

of a Nose cup Assembly.
Respirators  intended  for  routine  use  and  respirators  not  routinely 

used  but  kept  for  emergency  use  should  be  located  in  areas  where 

the temperature is maintained above freezing, +32°F / 0° C. Where it 

is expected that the respirator will be used in ambient temperatures 

near or below freezing, the respirator shall be equipped with a Nose 

cup Assembly to reduce the formation of vision impairing mist or ice 

on the interior of the facepiece vision area. Anti-Fog Applique is also 

available  to  reduce  facepiece  fogging  in  conditions  above  freezing, 

+32°F / 0° C. See ACCESSORIES.

If a respirator may be unavoidably kept at a temperature below freez-

ing before the next use, special care MUST be exercised to be certain 

that all components of the respirator are THOROUGHLY DRIED after 

cleaning and before storage. 

If  a  respirator  has  been  unavoidably  kept  at  a  temperature  below 

freezing and it is not possible to bring it to room temperature before 

it is used, the following modification to the USE OF THE RESPIRA-

TOR section is required: 

 

WHEN  USING A  NOSE  CUP ASSEMBLY  OR AN ANTI-FOG 

APPLIQUE, do not exhale into the facepiece until the facepiece 

is completely donned and the nose cup, if used, is properly in 

place against the face. 

noTe

EFFECTIVENESS OF ANTI-FOG APPLIQUE IN PREVENTING FOG-

GING  OR  MOISTURE  CONDENSATION  ON  INTERIOR  SURFACE  OF 

FACEPIECE  ASSEMBLY  MAY  DIMINISH  WITH  REPEATED  USES 

OR  OVER  TIME.  THE  APPLIQUE  CAN  BE  REPLACED  IF  IT  HAS 

DIMINISHED  IN  EFFECTIVENESS  OR  SUSTAINED  SUBSTANTIAL 

DAMAGE. SEE ACCESSORIES SECTION FOR REPLACEMENT KIT 

INFORMATION. 

Whenever  use  of  the  respirator  is  anticipated  in  areas  at  or  below 

freezing,  the  facepiece,  regulator,  airline  connection  hoses  and  air 

supply  hoses  MUST  be  protected  against  exposure  to  water  during 

storage. 

Содержание SKA-PAK AT

Страница 1: ...H ELECTRONIC ALARM WARNING IMPROPER USE OF THIS RESPIRATOR MAY RESULT IN PERSONAL INJURY OR DEATH IMPROPER USE INCLUDES BUT IS NOT LIMITED TO USE WITHOUT ADEQUATE TRAINING DISREGARD OF THE WARNINGS AN...

Страница 2: ...This respirator is not to be used under water for interior structural fire fighting or for any other purpose not authorized by the organized respiratory protection program that applies specifi cally t...

Страница 3: ...ration have one of five types of quick connect plugs and come in single or dual plug versions Dual plug versions provide a facil ity for transition between redundant air supply hoses On both the singl...

Страница 4: ...h a multipurpose Full Body Harness P N 805061 04 This harness is intended to be used only in accordance with both the user s respira tory protection program and fall protection program For additional...

Страница 5: ...this or similar equipment 5 Whether or not the cylinder is fully charged at the start of the use period 6 The possible presence in the compressed air of carbon dioxide concentrations greater than 04 n...

Страница 6: ...er After passing the NEGATIVE PRESSURE LEAK TEST the facepiece size selected must be verified by successfully passing a respirator Quantitative Fit Test When fit testing for Open Circuit Pressure Dema...

Страница 7: ...TEST and the Quantitative Fit Test If leakage is still detected either per these user instructions or the OSHA fit testing process the use of Mask Seal Kit P N 805655 01 may be required to attain a p...

Страница 8: ...eratures at or below freezing 32 F 0 C the condensation may freeze inside the air supply lines or inside the respirator possibly causing the flow of breathing air to be reduced or to stop completely N...

Страница 9: ...03904 01 air supply hoses may be interchanged to supply a single SKA PAK AT respirator and except for these different types of supply hose may NOT be mixed The 30010 series hose utilize a Hansen7 bras...

Страница 10: ...with the body of socket A as described in step 1 Slide sleeve B away from the body toward the supply hose to release the plug fitting from the socket IF IT IS NOT PRACTICAL TO SEE THE ALIGNMENT NOTCH...

Страница 11: ...e reducer using moderate force NOTES 11 SCOTT Part Number stamped into end of hose See FIGURE 2 12 SCOTT Part Number stamped into hose within 6 inches of either end 13 Specify silicone seals if orderi...

Страница 12: ...one of the following 9 volt batteries Energizer Alkaline No 522 or EN22 Duracell Alkaline No PC1604 or MN1604 or for increased service life use Ultralife Lithium Bat tery No U9VL Be sure battery is p...

Страница 13: ...Any trapped air will flow from the regulator Close the purge valve by rotating the knob to the full clockwise position when air flow stops CYLINDER INSPECTION NOTE IT IS THE RESPONSIBILITY OF THE USER...

Страница 14: ...on Page 4 and referenced in the DBI SALA full body harness user instructions SCOTT P N 89497 01 pro vided with the harness If any damage is found do not use the harness NOTE IF THE FULL BODY HARNESS H...

Страница 15: ...er and valve assembly is properly fitted to the harness Inspect the cylinder clamps Both clamps must be tight and hold the cylinder to the harness securely Tighten as necessary See FIGURE 6B FIGURE 6B...

Страница 16: ...ted on the nipple coupling that connects the pressure reducer to the cylinder valve To expose the threads and the gasket for inspection grasp the hand wheel coupling on the pressure reducer and turn t...

Страница 17: ...re must be taken to remove any dirt accumulations or obstructions from the fittings without allowing them to enter the air supply hose 6 Inspect the hose assembly that connects the pressure reducer to...

Страница 18: ...the facepiece as follows 1 Inspect the facepiece seal and other rubber components for de formation wear damage or cracks 2 Inspect the lens for cracks gouges scratches or any condition that could impa...

Страница 19: ...Cup is standard on the SCOTT AV 2000 Weld O Vista and AV 3000 full facepieces and optional on the SCOTT O VISTA full facepiece a SCOTT AV 3000 and AV 3000 SureSeal Facepieces are avail able with two d...

Страница 20: ...ize No air flow shall be detected at this time Inhale sharply to start the flow of air then take one breath and hold NOTE If the purge valve is adjusted to produce a flow it may not be possible to res...

Страница 21: ...OVIDE ADEQUATE PROTECTION FROM THE HAZARDOUS ATMOSPHERE WHICH MAY RESULT IN SERIOUS INJURY OR DEATH WARNING USE ONLY BREATHING AIR WHICH MEETS THE REQUIREMENTS AS DESCRIBED IN THE AIR SUPPLY REQUIREME...

Страница 22: ...such that the facepiece is toward the front of the wearer and the air supply cylinder is next to the left foot Pass the shoulder strap over the left shoulder and head onto the right shoulder Draw the...

Страница 23: ...ction or interference is suspected do not use the respirator until the problem is corrected Position the required length of air supply hose and prepare it for use by connecting the segments to each ot...

Страница 24: ...o the operating pressure of the respirator Repeat this step for each air supply hose and each air supply system to be used FIGURE 17 CONNECTING SUPPLY HOSE AND STANDBY CONDITION SHOWN WITH OPTIONAL NE...

Страница 25: ...ssure reducer is tight and that the breathing regulator purge valve red knob on regulator is closed knob turned fully clockwise Depress the air saver donning switch and release Connect the sup ply hos...

Страница 26: ...head harness to the head Periodically repeating the fit testing is required to identify any physical changes of the user such as those listed above which could affect the fit of the facepiece NOTE IF...

Страница 27: ...h chin properly located in the chin pocket while pulling the head harness over the top of the head Verify that no hair or clothing is interfering with the face to facepiece seal See FIGURE 19A 4 Tight...

Страница 28: ...n place with the chin properly located in the chin cup throughout the donning process 4 Stroke the head harness over the head and ensure that straps are lying smooth and flat against the head and neck...

Страница 29: ...temple strap end toward the rear of the head Alternate hands to maintain the facepiece position on the face 7 Verify the proper location of the face in the facepiece and the chin in the chin cup Tigh...

Страница 30: ...your head If necessary adjust the head harness net to the center of the crown of the head 10 Verify the proper location of the face in the facepiece and the chin in the chin cup Retighten the straps i...

Страница 31: ...o low on the face as evidenced by pres sure on the forehead or the facepiece making contact with the throat area permitting a break in the seal The illustrations below depict the AV 3000 SureSeal but...

Страница 32: ...ted as described under PREPARATION FOR USE 3 FULLY OPEN THE CYLINDER VALVE by turning the valve knob to the full counterclockwise position This will require approxi mately 2 1 2 complete rotations of...

Страница 33: ...on hose and transfer to another air supply hose is an ticipated during use of the respirator the user shall check the operation of the respirator as described above with each air supply hose and each...

Страница 34: ...knob The ELECTRONIC alarm shall flash both lights for approximately five seconds to ini tialize and stop The cylinder pressure gauge on the ELECTRONIC alarm shall read FULL The VIBRALERT shall NOT act...

Страница 35: ...xit from the area requiring respiratory protection is normally made by retracing the path used during entry so that exit can be made while air is supplied by the air supply system through the air supp...

Страница 36: ...upply hose for egress for instance if the hose is entangled or if it is necessary to exit by a different route the user shall disconnect the hose and immediately leave the area requiring respiratory p...

Страница 37: ...C Where it is expected that the respirator will be used in ambient temperatures near or below freezing the respirator shall be equipped with a Nose cup Assembly to reduce the formation of vision impa...

Страница 38: ...FAILURE TO THOROUGHLY RINSE AND COMPLETELY DRY THE ENTIRE FACEPIECE ASSEMBLY MAY ALLOW A BUILDUP OF DE TERGENTS AND OR DISINFECTING AGENTS WHICH COULD DAMAGE FACEPIECE COM PONENTS CLEANING THE FACEPI...

Страница 39: ...ening See FIGURE 22 Be sure to cover internal components completely 5 Follow the user instructions for the SCOTT recommended cleaner A specific contact time may be required for sanitizing or disinfect...

Страница 40: ...ORAGE WITH OUT THOROUGHLY DRYING THEM MAY RE SULT IN CORROSION OR OTHER DAMAGE WHICH COULD CAUSE A MALFUNCTION OF THE RESPIRATOR SUCH A MALFUNC TION MAY RESULT IN SERIOUS INJURY OR DEATH WARNING PLACI...

Страница 41: ...ed Test Equipment at least every two years16 However heavy use may require more frequent testing This recommendation is in addition to all other cleaning and maintenance procedures A manual covering t...

Страница 42: ...atter paint spray and abrasion 5 Dual airline connection hose assembly for redundant air sup ply hoses or to facilitate transfer between hoses H Type P N 804319 01 with standard Hansen fittings S Type...

Страница 43: ...D AIR SUPPLY APPROVED FOR USE AT TEMPERATURES ABOVE 25 F 32 C APPROVED ONLY WHEN THE COMPRESSED AIR CYLINDER IS FULLY CHARGED WITH AIR MEETING THE RE QUIREMENTS OF THE COMPRESSED GAS ASSOCIATION SPECI...

Страница 44: ...Page 44 of 44 P N 595189 01 Rev A 4 10 Health Safety Products Monroe Corporate Center PO Box 569 Monroe NC 28111 Telephone 1 800 247 7257 FAX 704 291 8330 www scotthealthsafety com Printed in USA...

Отзывы: