WArning

do  noT  uSe  The  Self-conTAined  Air 

SuPPly  for Any  PurPoSe  oTher  ThAn 

emergency  eScAPe.  if  The  Self-con-

TAined Air SuPPly hAS been dePleTed, 

There mAy be inSufficienT Air SuPPly 

for  eScAPe  Which  could  reSulT  in 

SeriouS inJury or deATh.

4.   Connect the respirator to the air supply system using one or more 

segments of air supply hose. There shall be no air flow from the 

facepiece. Don the facepiece or place it tightly against the face. 

Inhale  sharply  to  start  the  flow  of  air. Take  several  breaths. The 

VIBRALERT end of service time indicator and the ELECTRONIC 

alarm  shall  NOT  actuate. Air  shall  leave  the  facepiece  through 

the  exhalation  valve  on  exhalation  and  fresh  air  shall  flow  into 

the  facepiece  on  inhalation.  On  respirators  equipped  with  dual 

airline  connection  hoses,  remove  the  dust  cap  from  the  second 

plug and connect a second hose to the respirator. The respirator 

shall operate as described above. Disconnect the first hose. The 

respirator  shall  operate  as  described  above.  Cover  the  unused 

plug with the dust cap. 

 

At  the  completion  of  REGULAR  OPERATIONAL  INSPECTION, 

depress  the  air-saver/donning  switch,  doff  the  facepiece  and 

disconnect the respirator from the air supply source. Prepare the 

facepiece for donning by adjusting the head harness straps to the 

full out position. 

 

Verify that the air supply cylinder gauge is reading "FULL." If gauge 

is  reading  less  than  "FULL"  replace  air  supply  cylinder  with  one 

that is "FULL."

WArning

emergency SiTuATionS Tend To increASe 

breAThing rATe And, Therefore, To de-

creASe  The  AcTuAl  durATion  of  The 

Self-conTAined Air SuPPly. fAilure To 

TAKe Such fAcTorS inTo AccounT When 

uSing The reSPirATor for eScAPe mAy 

reSulT  in  Sudden  TerminATion  of 

breAThing  Air  Which  could  cAuSe 

SeriouS  inJury  or  deATh.

WArning

The Air SuPPly PreSSure muST remAin 

beTWeen 80 PSig And 115 PSig WiTh SuiT-

Able floW AT All TimeS during uSe. if 

The  Air  SuPPly  doeS  noT  mAinTAin 

T h e S e   r e Q u i r e m e n T S ,   T h e   r e S P i -

rATor  mAy  noT  Provide  AdeQuATe 

ProTecTion  from  The  hAZArdouS 

ATmoSPhere  Which  mAy  reSulT  in 

SeriouS  inJury  or  deATh.

WArning

uSe  only  breAThing Air  Which  meeTS 

The reQuiremenTS AS deScribed in The 

Air  SuPPly  reQuiremenTS  SecTion  of 

ThiS inSTrucTion. uSe of An Air SuPPly 

ThAT doeS noT meeT The reQuiremenTS 

could  reSulT  in  SeriouS  inJury  or 

deATh.

PrePArATion for uSe 

The purpose for the self-contained air supply on the SKA-PAK AT 

respirator is to provide breathable air during escape from objection-

able, oxygen deficient and/or unbreathable (toxic) atmospheres. 

If respirator use is expected at temperatures near or below freezing or 

if the respirator is to be stored in temperatures near or below freez-

ing, refer to LOW TEMPERATURE OPERATION section for additional 

information and supplemental procedures. 

Before  initiating  any  activity  which  requires  use  of  the  SKA-PAK AT 

respirator,  both  the  normal  exit  route  and  one  or  more  emergency 

escape routes to an area with a safe, breathable atmosphere shall be 

determined. During normal exit, the respirator will be supplied with air 

through  the  air  supply  hose  from  the  air  supply  system.  Emergency 

exit  routes  shall  be  such  that  they  can  be  travelled  using  the  self-

contained air supply. 

If  escape  cannot  be  safely  accomplished  within  the  limited  time  of 

respiratory protection provided by this respirator after the air supply 

hose is disconnected, DO NOT USE THIS RESPIRATOR; make what-

ever  changes  are  required  for  safety,  such  as  selecting  a  respirator 

of appropriate self-contained duration. 

Determine  the  amount  of  air  supply  hose  required  for  the  job  and 

ensure that it is less than or equal to the maximum allowable length 

of that type of hose. See Table 1. 

Be  certain  that  the  air  supply  system  is  providing  safe,  respirable 

breathing  air  and  is  compatible  with  the  air  supply  hose.  Be  certain 

that personnel who are knowledgeable in the operation of the air sup-

ply system are present to monitor and maintain the supply pressure 

at the point of attachment of the air supply hose(s) to the air supply 

system(s). 

Verify that the air supply cylinder gauge is reading "FULL." If gauge 

is reading less than "FULL" replace air supply cylinder with one that 

is "FULL."

Содержание SKA-PAK AT

Страница 1: ...H ELECTRONIC ALARM WARNING IMPROPER USE OF THIS RESPIRATOR MAY RESULT IN PERSONAL INJURY OR DEATH IMPROPER USE INCLUDES BUT IS NOT LIMITED TO USE WITHOUT ADEQUATE TRAINING DISREGARD OF THE WARNINGS AN...

Страница 2: ...This respirator is not to be used under water for interior structural fire fighting or for any other purpose not authorized by the organized respiratory protection program that applies specifi cally t...

Страница 3: ...ration have one of five types of quick connect plugs and come in single or dual plug versions Dual plug versions provide a facil ity for transition between redundant air supply hoses On both the singl...

Страница 4: ...h a multipurpose Full Body Harness P N 805061 04 This harness is intended to be used only in accordance with both the user s respira tory protection program and fall protection program For additional...

Страница 5: ...this or similar equipment 5 Whether or not the cylinder is fully charged at the start of the use period 6 The possible presence in the compressed air of carbon dioxide concentrations greater than 04 n...

Страница 6: ...er After passing the NEGATIVE PRESSURE LEAK TEST the facepiece size selected must be verified by successfully passing a respirator Quantitative Fit Test When fit testing for Open Circuit Pressure Dema...

Страница 7: ...TEST and the Quantitative Fit Test If leakage is still detected either per these user instructions or the OSHA fit testing process the use of Mask Seal Kit P N 805655 01 may be required to attain a p...

Страница 8: ...eratures at or below freezing 32 F 0 C the condensation may freeze inside the air supply lines or inside the respirator possibly causing the flow of breathing air to be reduced or to stop completely N...

Страница 9: ...03904 01 air supply hoses may be interchanged to supply a single SKA PAK AT respirator and except for these different types of supply hose may NOT be mixed The 30010 series hose utilize a Hansen7 bras...

Страница 10: ...with the body of socket A as described in step 1 Slide sleeve B away from the body toward the supply hose to release the plug fitting from the socket IF IT IS NOT PRACTICAL TO SEE THE ALIGNMENT NOTCH...

Страница 11: ...e reducer using moderate force NOTES 11 SCOTT Part Number stamped into end of hose See FIGURE 2 12 SCOTT Part Number stamped into hose within 6 inches of either end 13 Specify silicone seals if orderi...

Страница 12: ...one of the following 9 volt batteries Energizer Alkaline No 522 or EN22 Duracell Alkaline No PC1604 or MN1604 or for increased service life use Ultralife Lithium Bat tery No U9VL Be sure battery is p...

Страница 13: ...Any trapped air will flow from the regulator Close the purge valve by rotating the knob to the full clockwise position when air flow stops CYLINDER INSPECTION NOTE IT IS THE RESPONSIBILITY OF THE USER...

Страница 14: ...on Page 4 and referenced in the DBI SALA full body harness user instructions SCOTT P N 89497 01 pro vided with the harness If any damage is found do not use the harness NOTE IF THE FULL BODY HARNESS H...

Страница 15: ...er and valve assembly is properly fitted to the harness Inspect the cylinder clamps Both clamps must be tight and hold the cylinder to the harness securely Tighten as necessary See FIGURE 6B FIGURE 6B...

Страница 16: ...ted on the nipple coupling that connects the pressure reducer to the cylinder valve To expose the threads and the gasket for inspection grasp the hand wheel coupling on the pressure reducer and turn t...

Страница 17: ...re must be taken to remove any dirt accumulations or obstructions from the fittings without allowing them to enter the air supply hose 6 Inspect the hose assembly that connects the pressure reducer to...

Страница 18: ...the facepiece as follows 1 Inspect the facepiece seal and other rubber components for de formation wear damage or cracks 2 Inspect the lens for cracks gouges scratches or any condition that could impa...

Страница 19: ...Cup is standard on the SCOTT AV 2000 Weld O Vista and AV 3000 full facepieces and optional on the SCOTT O VISTA full facepiece a SCOTT AV 3000 and AV 3000 SureSeal Facepieces are avail able with two d...

Страница 20: ...ize No air flow shall be detected at this time Inhale sharply to start the flow of air then take one breath and hold NOTE If the purge valve is adjusted to produce a flow it may not be possible to res...

Страница 21: ...OVIDE ADEQUATE PROTECTION FROM THE HAZARDOUS ATMOSPHERE WHICH MAY RESULT IN SERIOUS INJURY OR DEATH WARNING USE ONLY BREATHING AIR WHICH MEETS THE REQUIREMENTS AS DESCRIBED IN THE AIR SUPPLY REQUIREME...

Страница 22: ...such that the facepiece is toward the front of the wearer and the air supply cylinder is next to the left foot Pass the shoulder strap over the left shoulder and head onto the right shoulder Draw the...

Страница 23: ...ction or interference is suspected do not use the respirator until the problem is corrected Position the required length of air supply hose and prepare it for use by connecting the segments to each ot...

Страница 24: ...o the operating pressure of the respirator Repeat this step for each air supply hose and each air supply system to be used FIGURE 17 CONNECTING SUPPLY HOSE AND STANDBY CONDITION SHOWN WITH OPTIONAL NE...

Страница 25: ...ssure reducer is tight and that the breathing regulator purge valve red knob on regulator is closed knob turned fully clockwise Depress the air saver donning switch and release Connect the sup ply hos...

Страница 26: ...head harness to the head Periodically repeating the fit testing is required to identify any physical changes of the user such as those listed above which could affect the fit of the facepiece NOTE IF...

Страница 27: ...h chin properly located in the chin pocket while pulling the head harness over the top of the head Verify that no hair or clothing is interfering with the face to facepiece seal See FIGURE 19A 4 Tight...

Страница 28: ...n place with the chin properly located in the chin cup throughout the donning process 4 Stroke the head harness over the head and ensure that straps are lying smooth and flat against the head and neck...

Страница 29: ...temple strap end toward the rear of the head Alternate hands to maintain the facepiece position on the face 7 Verify the proper location of the face in the facepiece and the chin in the chin cup Tigh...

Страница 30: ...your head If necessary adjust the head harness net to the center of the crown of the head 10 Verify the proper location of the face in the facepiece and the chin in the chin cup Retighten the straps i...

Страница 31: ...o low on the face as evidenced by pres sure on the forehead or the facepiece making contact with the throat area permitting a break in the seal The illustrations below depict the AV 3000 SureSeal but...

Страница 32: ...ted as described under PREPARATION FOR USE 3 FULLY OPEN THE CYLINDER VALVE by turning the valve knob to the full counterclockwise position This will require approxi mately 2 1 2 complete rotations of...

Страница 33: ...on hose and transfer to another air supply hose is an ticipated during use of the respirator the user shall check the operation of the respirator as described above with each air supply hose and each...

Страница 34: ...knob The ELECTRONIC alarm shall flash both lights for approximately five seconds to ini tialize and stop The cylinder pressure gauge on the ELECTRONIC alarm shall read FULL The VIBRALERT shall NOT act...

Страница 35: ...xit from the area requiring respiratory protection is normally made by retracing the path used during entry so that exit can be made while air is supplied by the air supply system through the air supp...

Страница 36: ...upply hose for egress for instance if the hose is entangled or if it is necessary to exit by a different route the user shall disconnect the hose and immediately leave the area requiring respiratory p...

Страница 37: ...C Where it is expected that the respirator will be used in ambient temperatures near or below freezing the respirator shall be equipped with a Nose cup Assembly to reduce the formation of vision impa...

Страница 38: ...FAILURE TO THOROUGHLY RINSE AND COMPLETELY DRY THE ENTIRE FACEPIECE ASSEMBLY MAY ALLOW A BUILDUP OF DE TERGENTS AND OR DISINFECTING AGENTS WHICH COULD DAMAGE FACEPIECE COM PONENTS CLEANING THE FACEPI...

Страница 39: ...ening See FIGURE 22 Be sure to cover internal components completely 5 Follow the user instructions for the SCOTT recommended cleaner A specific contact time may be required for sanitizing or disinfect...

Страница 40: ...ORAGE WITH OUT THOROUGHLY DRYING THEM MAY RE SULT IN CORROSION OR OTHER DAMAGE WHICH COULD CAUSE A MALFUNCTION OF THE RESPIRATOR SUCH A MALFUNC TION MAY RESULT IN SERIOUS INJURY OR DEATH WARNING PLACI...

Страница 41: ...ed Test Equipment at least every two years16 However heavy use may require more frequent testing This recommendation is in addition to all other cleaning and maintenance procedures A manual covering t...

Страница 42: ...atter paint spray and abrasion 5 Dual airline connection hose assembly for redundant air sup ply hoses or to facilitate transfer between hoses H Type P N 804319 01 with standard Hansen fittings S Type...

Страница 43: ...D AIR SUPPLY APPROVED FOR USE AT TEMPERATURES ABOVE 25 F 32 C APPROVED ONLY WHEN THE COMPRESSED AIR CYLINDER IS FULLY CHARGED WITH AIR MEETING THE RE QUIREMENTS OF THE COMPRESSED GAS ASSOCIATION SPECI...

Страница 44: ...Page 44 of 44 P N 595189 01 Rev A 4 10 Health Safety Products Monroe Corporate Center PO Box 569 Monroe NC 28111 Telephone 1 800 247 7257 FAX 704 291 8330 www scotthealthsafety com Printed in USA...