Page 10 of 44
P/N 595189-01 Rev A 4/10
TAble 1
limiTATionS And oPerATing inSTrucTionS for SuPPly hoSe
noTe: The Air SuPPly PreSSure muST be mAinTAined beTWeen 80 PSig And 115 PSig
While floWing AT leAST 200 liTerS Per minuTe (lPm) To eAch uSer.
A
b
c
A
b
c
A
b
c
A
b c
HANSEN HK COUPLING
USED ON 26369
SERIES
FOSTER COUPLING
USED ON 26370
SERIES
SCHRADER COUPLING
USED ON 30020
SERIES
HANSEN COUPLING
USED ON 30010 SERIES
figure 3
couPlingS uSed on SuPPly hoSeS
A b
c
CEJN COUPLING
USED ON 805659
SERIES
WArning
The uSer of ThiS reSPirATor mAy hAve To diSconnecT The hoSe couPling Suddenly And under
STreSSful condiTionS. The uSer muST be Able To diSconnecT The couPling under The condi-
TionS Which mAy be encounTered during uSe, for exAmPle, WiThouT being Able To See The
couPling, WiTh gloveS on, WiTh one hAnd, eTc. fAilure of The uSer To AdeQuATely Perform
TheSe TASKS under STreSSful condiTionS mAy reSulT in SeriouS inJury or deATh.
inSTrucTionS for oPerATion of couPlingS
note: The user shall practice and be able to discon-
nect the couplings quickly in an emergency situation.
1. To connect the coupling, rotate socket sleeve "B" until
the alignment notch in the sleeve is in line with align-
ment peg in body "A".
2. Slide sleeve "B" toward the supply hose (away from plug
"C") and insert plug "C" into socket "A". Release sleeve
"B" while pushing the plug into the socket until engaged,
as evidenced by a "click". Test for positive engagement
by tugging on the plug.
3. Rotate sleeve "B" one-quarter to one-half turn to lock
the plug against accidental release.
4. To disconnect the coupling, realign sleeve "B" with the
body of socket "A" as described in step 1. Slide sleeve
"B" away from the body (toward the supply hose) to
release the plug fitting from the socket.
IF IT IS NOT PRACTICAL TO SEE THE ALIGNMENT
NOTCH IN THE SLEEVE, USE THE FOLLOWING
PROCEDURE TO DISCONNECT THE COUPLING:
1. Grasp sleeve "B" with the right hand.
2. Simultaneously rotate and push the sleeve away from the
plug until the alignment notch in the sleeve lines up with
the alignment peg in the body and the socket separates
from the plug.
1
The female connectors on all supply hose series are checked to stop the flow of air when they are disconnected. Both male and
female connectors are checked on 26369 series supply hose.
2
"0" feet = direct connection to air supply source.
3
Segments of supply hose are commonly available in 25 ft, 50 ft, 75 ft, and 100 ft length segments.
Supply hose
1
30010 Series with
brass Hansen cou-
plings
26369 Series
with stainless steel
Hansen HK
couplings
30020 Series with
steel Schrader cou-
plings
805659 Series with
brass CEJN cou-
plings
0 to 300
0 to 300
0 to 150
0 to 300
0 to 300
1. Insert plug fitting "C" into socket "A" and continue
pushing until it is engaged as evidenced by a "click".
2. Test for positive engagement by tugging on the plug.
3. Disconnect the coupling by pushing in on plug "C" while
pulling back on sleeve "B". Plug "C" will separate.
1. Insert plug fitting "C" into socket "A" and continue
pushing until it is engaged as evidenced by a "click".
2. Test for positive engagement by tugging on the plug.
3. Disconnect the coupling by rotating sleeve "B" 1/8
turn in the clockwise direction as viewed from the
female end of socket "A".
Approved
Total
lengths
2
(in ft)
maximum number
of Segments Ap-
proved
3
6
12
12
12
12
26370-Series or
200820-Series,
or 803904-01 Hose
with stainless steel
Foster couplings