Appendix
94 / 96
EN
· 30.30.01.02851 · 01 · 03/22
141
0x008D
0
cc2
Valve operating
counter
4 bytes
ro
Not erasable (stored every
1000 counts)
142
0x008E
0
cc3
Condition
monitoring
counter
4 bytes
ro
Not erasable (stored every
1000 counts)
143
0x008F
0
ct1
Erasable
vacuum-on
counter
4 bytes
ro
Can be reset by system
command “Reset erasable
counters” (stored every 1000
counts)
144
0x0090
0
ct2
Erasable valve
operating
counter
4 bytes
ro
Can be reset by system
command “Reset erasable
counters” (stored every 1000
counts)
145
0x0091
0
ct3
Erasable
condition
monitoring
counter
4 bytes
ro
Can be reset by system
command “Reset erasable
counters” (stored every 1000
counts)
Diagnosis
Device status
32
0x0020
0
Error Count
2 bytes
ro
Number of errors since last
power-up
36
0x0024
0
IO-Link Device
Status
1 byte
ro
0 = Device is operating
properly
1 = Maintenance required
2 = Out of specification
3 = Functional check
4 = Failure
37
0x0025
0
Detailed Device
Status
96 bytes
ro
Information about currently
pending events
Fixed-length array format
according to IO-Link
specification V1.1
130
0x0082
0
Active Errors
2 bytes
ro
Bit 00: Internal error: data
corruption (E01)
Bit 01: Reserved
Bit 02: Primary voltage too low
(E07)
Bit 03: Primary voltage too
high (E17)
Bit 04
–07: Reserved
Bit 08: Short circuit at OUT2
(E12)
Bit 09
–10: Reserved
Bit 11: Measurement range
overrun (FFF)
Bit 12
–14: Reserved
Bit 15: IO-Link communication
interruption (E08)
138
0x008A
1
Extended
Device Status -
Type
1 byte
ro
Type code of active device
status (see below)
138
0x008A
2
Extended
Device Status -
ID
2 bytes
ro
ID code of active device status
(see below, corresponds to IO-
Link events)
139
0x008B
0
NFC Status
1 byte
ro
Result of recent NFC activity:
0x00 Data valid, write finished
successfully
0x23: Write failed: Write
access locked
0x30: Write failed:
parameter(s) out of range
0x31: Write failed: parameter
value too high
0x32: Write failed: parameter
value too low
0x41: Write failed: parameter
set inconsistent
0xA1: Write failed: invalid
authorization
0xA2: NFC not available
0xA3: Write failed: invalid data
structure
0xA5: Write pending
0xA6: NFC internal error
Condition Monitoring [CM]
146
0x0092
0
Condition
monitoring
2 bytes
ro
Bit 0: Valve protection active
Bit 1: Evacuation time t1 above
limit [t-1]
Bit 2: Leakage rate above limit
[-L-]
Bit 3: SP1 not reached in
suction cycle
Bit 4: Free-flow vacuum > rP2
but < SP1
Bit 5: Primary voltage US
outside of optimal range
Bit 6: Reserved
Bit 7: Reserved
Bit 8: Input pressure outside of
operating range
Bit 9
–15: Reserved
Energy Monitoring [EM]
155
0x009B
0
Air
consumption
per cycle in
percent
1 byte
ro
Air consumption of last suction
cycle (unit: 1%)