Description of Functions
46 / 96
EN
· 30.30.01.02851 · 01 · 03/22
7.8
Selecting a Display Unit [0x004A]
The unit of the displayed vacuum level can be set using this function.
The function can be configured using the
parameter or via IO-Link.
The following units are available:
Unit
Explanation
bar
The vacuum level is displayed in mbar.
The setting for this unit is
.
Pascal
The vacuum level is displayed in kPa.
The setting for this unit is
.
Inch of Hg
The vacuum level is displayed in inHg.
The setting for this unit is
.
psi
The vacuum level is displayed in psi.
The setting for this unit is
.
Selection of the unit only affects the display. The units of the parameters that can be accessed via IO-Link
are not affected by this setting.
7.9
Switch-Off Delay [0x004B]
You can use this function to set a switch-off delay for the SP1 and SP2 signals. This can be used to handle short drops
in the vacuum circuit.
The duration of the switch-off delay can be set with the parameter
in the EF menu or via IO-Link. Select a value
in the range from 0 to 999 ms. To deactivate this function, enter the value
(= off).
The switch-off delay affects the process data bits in IO-Link and the SP1 and SP2 status indicators.
7.10
Rotating the Display [0x004F]
To allow different installation positions, the orientation of the display can be rotated by 180° by changing the
parameter
in the EF menu or via IO-Link.
The factory setting is
. This corresponds to the standard configuration.
To rotate the display by 180°, select the parameter setting
.
The
and
still work as usual when the display has been rotated.
The decimal points of the display are shown on the top edge of the screen.
7.11
ECO Mode [0x004C]
The area gripper provides the option to switch off or dim the display to save energy. If ECO mode is activated, the
display is switched off to reduce system power consumption after 1 minute if no buttons are pressed.
ECO mode can be enabled and disabled with the parameter
in the EF menu or via IO-Link.
Three different settings are available:
•
: Energy-saving mode is disabled.
•
: The brightness of the display is reduced by 50 percent after 1 minute.
•
: The display switches off after 1 minute of inactivity.