Installation
EN
· 30.30.01.02851 · 01 · 03/22
67 / 96
9.8
Mounting the Plastic Protective Cap
1
Control unit
2
Fastening screws for ejector assembly
3
Main body
4
Plastic protective cap
5
Machine screws for plastic cap
The plastic protective cap can be replaced if it is damaged. You must loosen the four fastening screws (2) to replace it.
You must also remove the two machine screws (5). The cap can then be removed. Mount the new cap in the reverse
order.
9.9
Mounting the Electrical Connection
NOTE
Change of output signals when product is switched on or plug is connected
Personal injury or damage to property
Electrical connection must be performed only by a qualified specialist who can predict the effects
that signal changes will have on the entire system.
NOTE
Incorrect power supply
Destruction of the integrated electronics
Operate the product using a power supply unit with protected extra-low voltage (PELV).
The system must incorporate safe electrical cut-off of the power supply in compliance with EN60204.
Do not connect or disconnect the connector under tension and/or when voltage is applied.
2
3
1
4
5