Description of Functions
48 / 96
EN
· 30.30.01.02851 · 01 · 03/22
1.
Use the
button to enter the first digit of the PIN code.
2.
Use the
to confirm the first digit and go to entry of the second digit.
3.
Repeat this process to enter all the digits of the PIN code.
When a valid PIN is entered, the message [VnC] is displayed.
When an invalid PIN is entered, the message [Loc] is displayed and the menus remain locked.
Once the PIN has been entered successfully, you will have one minute to edit the parameter in question.
The PIN code in the
parameter must be set to 000 in order to permanently deactivate the lock.
The PIN is set to 000 on delivery. The menus are not protected.
If you cannot remember the correct PIN code, read or reset the PIN code via IO-Link or
use NFC to reset it to the factory settings.
7.13
Restricting Access Using Device Access Locks [0x000C]
In IO-Link mode, the “Device Access Locks” default parameter is available
to prevent changes to parameter values using the operating element of the ejector.
A menu lock using the Device Access Locks parameter has a higher priority than the menu PIN. In other words, this
lock cannot be bypassed by entering a PIN, and remains in place.
It can only be canceled using IO-Link, not on the ejector itself.
7.14
Restricting Access with Extended Device Access Locks [0x005A]
The Extended Device Access Locks gives you the following options:
•
Block all NFC access or restrict it to read-only functions. The NFC lock using the extended device access locks
parameter has a higher priority than the NFC PIN. That means that this lock also cannot be bypassed by entering
a PIN.
•
Block the use of manual mode.
•
Block the transmission of IO-Link events.
7.15
Resetting to Factory Settings (Clear All) [0x0002]
This function is used to reset the following configurations to their factory settings:
•
The configuration of the area gripper
•
The initial setup
•
The production setup profile settings
•
The IO-Link parameter “Application specific tag”
This function is executed using the parameter
in the EF menu or via IO-Link.
The factory settings for the area gripper are listed in the Technical Data section.