Operation
70 / 96
EN
· 30.30.01.02851 · 01 · 03/22
10
Operation
Always carry out the following tasks before activating the system:
1.
Before each use, check that the safety features are in perfect condition.
2.
Check the area gripper for visible damage and deal with any problems immediately or notify your
supervisor.
3.
Ensure that only authorized personnel are present in the working area of the machine or system and that
no other personnel are put in danger by switching on the machine.
There must be no people in the system’s danger area while it is in operation.
10.1
Safety
NOTE
Incorrect control when depositing products
The product cannot be released from the gripper. Increased wear on the sealing elements.
The dynamic pressure in the gripper must not be more than 0.2 bar during blow-off.
Before initiating the blow-off pulse, ensure that the gripper (with attached workpiece) is not pressed
against a solid surface. The workpiece must be able to freely detach from the gripper.
NOTE
Risk of implosion with closed containers
Containers such as cups can implode if the vacuum is too high. Possibility that contents will leak out.
Carry out tests in advance and adjust the maximum vacuum.
NOTE
Noise pollution due to the escape of compressed air / exhaust air
Discomfort
The system must only be operated with a silencer.
Wear ear protectors.
Regular maintenance and inspection of all components.
NOTE
Limitation of the function due to moisture
The area gripper is only protected against moisture to a limited extent.
Avoid use in damp conditions.