Appendix
EN
· 30.30.01.02851 · 01 · 03/22
95 / 96
156
0x009C
0
Air
consumption
per cycle
2 bytes
ro
Air consumption of last suction
cycle (unit: 0.1 Nl)
157
0x009D
0
Energy
consumption
per cycle
2 bytes
ro
Energy consumption of last
suction cycle (unit: 1 Ws)
Predictive Maintenance [PM]
162
0x00A2
0
Quality
1 byte
ro
Quality of last suction cycle
(unit: 1%)
163
0x00A3
0
Performance
1 byte
ro
Last measured performance
level (unit: 1%)
Coding of extended device status (ISDU 138) and IO-Link events
Extended device status ID
Extended device status type
IO-Link
Display code
Event name
Remarks
(= IO-Link event code)
Event type
dec
hex
hex
Meaning
0
0x0000
0x10
Everything OK
(no IOL
event)
Everything OK
Device is working optimally
6161
0x1811
0x82
Defect/fault,
high
Error
E01
Data corruption
Internal error, user data
corrupted
35872
0x8C20
0x81
Defect/fault,
lower
Error
FFF
Measurement range overrun
Measured vacuum value too
high, sensor fault
2457
0x0999
0x81
Defect/fault,
lower
(no IOL
event)
E08
IO-Link communication interruption
IO-Link communication is
interrupted (readable via NFC)
20736
0x5100
0x42
Critical
condition, high
Error
E07
General power supply fault
Primary supply voltage (US)
too low
20752
0x5110
0x42
Critical
condition, high
Warning
E17
Primary supply voltage over-run
Primary supply voltage (US)
too high
6146
0x1802
0x42
Critical
condition, high
Warning
Supply pressure fault
Input pressure too high or too
low
6156
0x180C
0x22
Warning, high
Warning
Primary supply voltage out of optimal range
Condition monitoring: primary
supply voltage US outside of
operating range
6151
0x1807
0x22
Warning, high
Warning
CM: Valve protection active
Condition monitoring: valve
has switched too fast,
continuous
suction activated
6152
0x1808
0x21
Warning, low
Warning
CM: Evacuation time above limit
Condition monitoring:
evacuation time t1 is above
limit [t-1]
6153
0x1809
0x21
Warning, low
Warning
CM: Leakage rate above limit
Condition monitoring: leakage
rate is above limit [-L-]
6154
0x180A
0x22
Warning, high
Warning
CM: SP1 not reached
Condition monitoring: vacuum
level SP1 was never reached
during
suction cycle
6155
0x180B
0x21
Warning, low
Warning
CM: Free-flow vacuum too high
Condition monitoring: free-flow
vacuum above SP2
35841
0x8C01
0x21
Warning, low
Warning
Simulation active
Manual mode is active
6144
0x1800
-
(IOL event
only)
Notification
Vacuum calibration OK
Calibration offset 0 set
successful
6145
0x1801
0x22
Warning, high
Notification E03
Vacuum calibration failed
Sensor value too high or too
low, offset not changed
6167
0x1817
-
(IOL event
only)
Notification
Autoset completed successfully
Permissible leakage and
permissible evacuation time
have been set
automatically for the active
profile
6168
0x1818
-
(IOL event
only)
Notification
Handling cycle completed
Handling of the part is
complete (neutral state of
vacuum system reached
or new suction phase begun)
30480
0x7710
0x41
Critical
condition, low
Error
E12
Short circuit at OUT2
Output is connected with
counterpotential