Appendix
EN
· 30.30.01.02851 · 01 · 03/22
91 / 96
CM Autoset
3
Boolean
wo
Perform CM Autoset function (teach permissible
leakage and
permissible evacuation time)
EPC-Select 0
4
Boolean
wo
Select the function of EPC values 1 and 2 (2-bit binary
coded)
(see PD In Byte 1 to 3)
EPC-Select 1
5
Boolean
wo
Profile-Set 0
6
Boolean
wo
Select production profile (2-bit binary coded)
(see ISDU parameter areas P0 to P3)
Profile-Set 1
7
Boolean
wo
PD Out Byte 1
Input pressure
7…0 8-bit integer
wo
Pressure value from external sensor (unit: 0.1 bar)
ISDU parameters
ISDU index
Subindex
Display
appearance
Parameter
Size
Value range
Access
Default value /
Example
Remarks
dec
hex
dec
Identification
Device Management
16
0x0010
0
Vendor Name
1 to 32
bytes
ro
J. Schmalz GmbH
Manufacturer designation
17
0x0011
0
Vendor text
1 to 32
bytes
ro
Internet address
18
0x0012
0
Product Name
1 to 32
bytes
ro
FXP-i/FMP-i
General product name
19
0x0013
0
Product ID
1 to 32
bytes
ro
FXP-i/FMP-i
Product variant name
20
0x0014
0
Product text
1 to 32
bytes
ro
EJEK-BG FXP-i 75-HV
NC/VENT-BGR FMP-i-32 NC
Order code
21
0x0015
0
Sno.
Serial Number
9 bytes
ro
000000001
Serial number
22
0x0016
0
Hardware
Revision
2 bytes
ro
03
Hardware revision
23
0x0017
0
SoC
Firmware
Revision
4 bytes
ro
Mar. 01
Firmware revision
240
0x00F0
0
Unique ID
20 bytes
ro
Unique device identification
number
241
0x00F1
0
Device
Features
11 bytes
ro
Type code of device features
(see IODD)
250
0x00FA
0
Art
Article Number
14 bytes
ro
10.01.38.*
Order number
251
0x00FB
0
Article Revision
2 bytes
ro
00
Article revision
252
0x00FC
0
Production
Date
3 bytes
ro
D21
Date code of production
(month+year, month is letter
coded,
e.g. D21 = April 2021)
254
0x00FE
0
Detailed
product text
1 to 64
bytes
ro
EJEK-BG FXP-i 75-HV
NC/VENT-BGR FMP-i-32 NC
Detailed type description of the
device
Device Localization
24
0x0018
0
Application
Specific Tag
1 to 32
bytes
rw
***
User string to store location or
tooling information
242
0x00F2
0
Equipment
Identification
1 to 64
bytes
rw
***
User string to store
identification name from
schematic
246
0x00F6
0
Geolocation
1 to 64
bytes
rw
***
User string to store
geolocation from handheld
device
247
0x00F7
0
IODD Web Link
1 to 64
bytes
rw
***
User string to store web link to
IODD file
248
0x00F8
0
NFC Web Link
1 to 64
bytes
http://…
https://…
rw
https://myproduct.schmalz.com/#/
Web link to NFC app (base
URL for NFC tag)
249
0x00F9
0
Storage
Location
1 to 32
bytes
rw
***
User string to store storage
location
253
0x00FD
0
Installation
Date
1 to 16
bytes
rw
***
User string to store date of
installation
Parameter
Device Settings
Commands
2
0x0002
0
System
Command
1 byte
5, 130, 165,
167, 168, 169
wo
0x05 (dec 5): Force upload of
parameter data into the master
0x82 (dec 130): Restore
device parameters to factory
defaults
0xA5 (dec 165): Calibrate
vacuum sensor
0xA7 (dec 167): Reset
erasable counters ct1, ct2, ct3
0xA8 (dec 168): Reset
voltages HI/LO
0xA9 (dec 169): Reset
vacuum/pressure HI/LO
Access Control
12
0x000C
0
Device Access
Locks
2 bytes
0, 4
rw
0
Bit 0
–1: reserved
Bit 2: Local parameterization