innovators for industry
Ctrl Command set_softstart_level
Function
sets the softstart values.
Call
set_softstart_level( Index, Level )
Parameters
All parameters must be unsigned 32-bit values.
Parameter
Allowed Values
Description
Index
0 … 1023
index number of the softstart table value
Level
0 … 2
12
–1
0 … (2
32
-1)
for softstart mode = 1, 2, 11 and 12 (see
).
Value 0 corresponds to an analog voltage value of 0 V; value 2
12
–1
corresponds to 10 V.
for softstart mode = 3 and 13 (see
1 bit corresponds to a pulse length of 1/64
µ
s (in RTC
®
5 mode) or 1/8
µ
s
(in RTC
®
4 compatibility mode).
Comments
• The
set_softstart_level
command defines the
Level
value for the pulse number
Index
.
The command must be called separately for each individual
Level
value.
•
Index
must be in the range [0…1023], otherwise the
set_softstart_level
command will
not be executed (
return code
RTC5_PARAM_ERROR
).
• If
Index
Number
(
Number
is defined via
set_softstart_level
will be executed but the defined value will not be used during softstart.
• Be sure to set as many softstart values as you defined by
(unspec-
ified softstart values have undefined contents).
• The softstart mode is enabled by the command
.
• For softstart modes 1, 2, 11 or 12,
Level
is restricted to 12 bits; higher bits will be
or
• If Softstart mode = 3 or 13 and the specified softstart pulse length is larger than the
laser signal period duration specified via
(2 ·
HalfPeriod
), then the laser will remain continuously on.
• Particularly if softstart values are to be outputted as analog voltage values (softstart
mode = 1, 2, 11 or 12), the
command must be called
before
first-
time use of the
set_softstart_level
command; otherwise the specified value will not be
correctly converted to an analog value.
• Also observe the note in section
.
• If the “freely definable wobbel shape“ wobbel mode is activated, then this command
will have no effect; see
chapter 8.4 "Wobbel Mode", page 167
.
RTC
®
4
RTC
®
5 essentially unchanged functionality (except for the extended range of values)
In RTC
®
4 compatibility mode, analog voltage levels are internally multiplied by 4 (here
2
10
–1 corresponds to 10 V; the values are converted from 10 to 12 bits) and pulselenght
values are multiplied by 8 (here 1 bit corresponds to 1/8
µ
s; the values are converted from
units of 1/8
µ
s to units of 1/64
µ
s; the 1
µ
– is no longer
supported). The permissible range of values for
Level
is correspondingly smaller. Due to
this difference in the handling of analog voltage and pulselenght values,
must always be called before
set_softstart_level
.
References
,