RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
383
innovators for industry
Call
range_checking ( HeadNo, Mode, Data )
Parameter
HeadNo
scan head to be monitored as an unsigned 32-bit value.
0:
1:
Primary scan head is monitored.
2:
Secondary scan head is monitored.
3:
Both scan heads are monitored.
Only the 2 least significant bits are evaluated.
Mode
action to take as an unsigned 32-bit value.
0:
Laser is switched-off immediately and list execution
continues.
1:
Laser is switched-off immediately and list execution
is stopped immediately (as with
/STOP
).
Data
data type chosen to be monitored as an unsigned 32-bit value.
0:
Sample values (Processing-on-the-fly and Wobbel corrected,
as with
signal types 7–9).
1:
Transformed control values (with scan head-specific
transformations, as with
signal types 25–30).
2:
Corrected control values (with correction file,
as with
signal types 10–15).
3:
Actual output values (with “Offset” and “Gain”,
as with
signal types 20–23).
4:
Real position of galvanometer (only with i
DRIVE
®
systems,
vario
SCAN
is internally connected to an X axis,
signal types 1, 2 and 3).
5:
Real position of galvanometer (only with i
DRIVE
®
systems,
vario
SCAN
is internally connected to an Y axis,
signal types 1, 2 and 4)
Undelayed
Short List
Command
range_checking