RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
459
innovators for industry
Ctrl Command set_mcbsp_y
Function
activates or deactivates Y offset correction for online positioning via the McBSP interface.
Call
set_mcbsp_y( Scale )
Parameter
Scale
Value as a 64-bit IEEE floating point number:
2
–26
<
Scale
< 2
26
: scaling factor (correction will be activated)
otherwise: correction will be deactivated
Comments
• For online positioning, see
.
• With an McBSP input value of Y
in
for the Y offset correction, the command
will function like
set_offset( …, YOffset, … )
, whereby
YOffset
(in bits)
= Scale
·
Y
in
YOffset
values outside of [–524288 … +524287] will be clipped to the boundaries as
long as
Scale
·
Y
in
doesn’t exceed the value range ±2
31
.
• The McBSP interface can’t be simultaneously used for both online positioning and
Processing-on-the-fly applications (see
RTC
®
4
RTC
®
5 new command
Version info
Available beginning with version DLL 524, OUT 526
References
,
Undelayed
Short
List Command
set_mcbsp_y_list
Function
same as
(see above), but a list command
Call
set_mcbsp_y_list( Scale )
Parameter
Scale
See
Comments
• See
RTC
®
4
RTC
®
5 new command
Version info
Available beginning with version DLL 524, OUT 526
References
Ctrl Command set_multi_mcbsp_in
Function
activates a Processing-on-the-fly application and McBSP multi transmission with up to
eight different data types.
Restriction
If the Processing-on-the-fly option is not enabled, then the command switches off the
Processing-on-the-fly process (even if it was never switched on).
Call
set_multi_mcbsp_in( Ctrl, P, Mode )
Parameter
Ctrl
control parameter for initializing or deactivating laser power variation as an
unsigned 32-bit value:
= 1…6: defines which signal parameter to vary: for a description, see
= 0 or > 6: deactivates laser power variation (if
Ctrl
r
eturn code
RTC5_PARAM_ERROR
).
P
Initialization value for laser power as an unsigned 32-bit value. For the
allowed range, see