RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
348
innovators for industry
RTC
®
4
RTC
®
5 unchanged functionality (except for changed value ranges and error codes)
If the correct calibration factors are used (see
), then the same ABC coefficients
can be used on the same 3-axis scan system with the RTC
®
4 and RTC
®
5 boards.
Version info
Last change with version DLL 516
References
Normal
List Command
long_delay
Function
pauses further processing of the list for the specified time
Call
long_delay( Delay )
Parameter
Delay
delay time in
bits
as an unsigned 32-bit value.
1 bit equals 10
µ
s
. Allowed range: 0
delay
(2
32
–1).
Comments
• This command (if applicable) switches off the “laser active” laser control signals after a
LaserOff delay, waits for a possible scanner delay and pauses further processing of the
list for the specified time.
• This command should always be called after changing the lamp current of a YAG laser
to obtain a constant laser power.
• The command
corresponds to
long_delay( 1 )
.
RTC
®
4
RTC
®
5 unchanged functionality (except for the increased range of values)
Ctrl Command load_z_table