RTC
®
5 PC Interface Board
Rev. 1.9 e
7 Basic Functions for Scan Head and Laser Control
131
innovators for industry
7.4.3 CO
2
Mode
The command
set_laser_mode(0)
selects the CO
2
laser mode (laser mode 0). The laser control timing
diagram
shows the corresponding signals.
For “laser active” operation (if applicable after a
LaserOn delay and if enabled via
or
)
• The LASERON signal is switched on and
• Two alternating modulation signals are provided
at the LASER1 and LASER2 outputs with pulse
lengths and periods that can be defined via
or
For “laser standby” operation (if applicable after a
LaserOff delay)
• The LASERON signal is switched off and
• Alternating standby pulses are provided at the
LASER1 and LASER2 outputs with pulse lengths
and periods that can be defined via
Time
LaserOff
Delay
LaserOn
Delay
LASERON
"Laser active"
"Laser standby"
"Laser standby"
Vector
Output
Start of
Vector
End of
Vector
½ Standby
Period
Standby
Pulse Width
LASER1
LASER2
½ Output
Period
Pulse Width
48
CO
2
mode
Laser control timing diagram for CO
2