RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
477
innovators for industry
Normal
List Command
set_serial_step_list
Function
sets the starting serial number and the increment size for the serial-number-set most
recently selected via
(or for serial-number-set 0 after
Call
set_serial_step_list( No, Step )
Parameters
No
Serial number as an unsigned 32-bit value; allowed range: [0 … (2
32
–1)]
Step
Increment size as an unsigned 32-bit value;
allowed range: [0 … 9999]; only the last 4 decimal digits are used.
Comments
• During initialization, the starting serial number (for
is set to 0 and the increment size set to 1.
• If
2
= 1 (i.e. automatic serial-
number incrementing was deactivated), then the increment size setting will have no
effect.
• If
Step
= 0, then incrementing will not occur, except in the case of markless marking
:
digits
= 0), which always increments serial
numbers by 1.
chapter 7.5.2 "Marking Serial Numbers", page 150
.
RTC
®
4
RTC
®
5 new command
Version info
Available beginning with version DLL 537, OUT 537
References
Ctrl Command set_sky_writing
Function
activates or deactivates Sky Writing mode and sets the corresponding parameters
Call
set_sky_writing( Timelag, LaserOnShift )
Parameters
Timelag
LaserOnShift
Comments
• The command is identical to
(
Timelag
,
LaserOnShift
,
Nprev
,
Npost
)
with
Nprev
= approx. (0.15 ·
Timelag
) and
Npost
= approx. (0.1 ·
Timelag
).
and
.
RTC
®
4
RTC
®
5 new command
References