![Savch S3100A Series Скачать руководство пользователя страница 52](http://html.mh-extra.com/html/savch/s3100a-series/s3100a-series_user-manual_1203758052.webp)
48
09 Accessibility parameters
indicates that the parameters can be set during operation.
Parame
ter
Parameter function
Setting range
Factory
setting
09-03
Acceleration time 2
0.0s
~
6500.0s
Type
setting
09-04
Deceleration time 2
0.0s
~
6500.0s
09-05
Acceleration time 3
0.0s
~
6500.0s
09-06
Deceleration time 3
0.0s
~
6500.0s
09-07
Acceleration time 4
0.0s
~
6500.0s
09-08
Deceleration time 4
0.0s
~
6500.0s
09-09
Jump frequency 1
0.00Hz
~
max frequency
0.00Hz
09-10
Jump frequency 2
0.00Hz
~
max frequency
0.00Hz
09-11
Jump frequency Amplitude
0.00Hz
~
max frequency
0.00Hz
09-12
Forward and reverse dead time
0.0s
~
3000.0s
0.0s
09-13
Reverse control enable
0:Enabled 1:Disabled
0
09-14
Operating mode with set
frequency lower than lower limit
frequency
0:Run at the lower limit frequency
1:Downtime
2:Zero speed operation
0
09-15
Drop control
0.00Hz
~
10.00Hz
0.00Hz
09-16
Set cumulative power-on arrival
time
0h
~
65000h
0h
09-17
Set cumulative running arrival
time
0h
~
65000h
0h
09-18
Power-on operation protection
options
0:Run command is valid when power on
1:Run command is invalid when power on
1
09-19
Frequency detection value(FDT1) 0.00Hz
~
max frequency
50.00Hz
09-20
Frequency detection
hysteresis(FDT1)
0.0%
~
100.0%(FDT1
Level)
5.0%
09-21
Frequency reach detection width
0.0%
~
100.0%(
max frequency)
0.0%
09-22
Whether the jump frequency is
effective during acceleration and
deceleration
0:Invalid
1:Valid
0
09-25
Switching frequency point
between acceleration time 1 and
acceleration time 2
0.00Hz
~
max frequency
0.00Hz
09-26
Switching frequency point
between deceleration time 1 and
deceleration time 2
0.00Hz
~
max frequency
0.00Hz
09-27
Terminal jogging priority
0:Invalid 1:Valid
0
09-28
Frequency detection value(FDT2)
0.00Hz
~
max frequency
50.00Hz
09-29
Frequency detection
hysteresis(FDT2)
0.0%
~
100.0%(FDT2
Level)
5.0%
09-30
Arbitrary arrival frequency
detection value 1
0.00Hz
~
max frequency
50.00Hz
Содержание S3100A Series
Страница 1: ...S3100Aseries inverter General Open loop Vector Control IM User manual User Manual ...
Страница 23: ...19 Size 3 Unit mm S3100A 2T5 5G 2T7 5G S3100A 4T7 5G 11P 4T18 5G 22P Size 4 Unit mm S3100A 4T22G 30P 4T37G 45P ...
Страница 24: ...20 Size 5 Unit mm S3100A 4T45G 55P 4T110G Size 6 Unit mm S3100A 4T110G 132P 4T160G 185P ...
Страница 25: ...21 Size 7 Unit mm S3100A 4T185G 200P 4T220G Size 8 Unit mm S3100A 4T220G 250P 4T315G ...
Страница 26: ...22 Size 9 Unit mm S3100A 4T315G 355P 4T400G 450P Size 10 Unit mm S3100A 4T450G 500P 4T500G ...