2.3.2 General specification
Item
Detailed information
C
on
tro
l c
ha
ra
cte
ris
tic
Control mode
V/f control, open loop vector control, torque control
range of output frequency
0
~
500.00Hz(V/f highest 3200.0Hz)
Frequency setting
resolution
0.01 Hz
Output Frequency setting
resolution
0.01 Hz
PWM carrier frequency
adjust from 0.5khz to 12khz
Torque boost
open loop vector control(SVC):G type:0.5Hz/150%
,
P type:0.5 Hz/120%
V/f curve
Three types:line, multi-point. Nth power V/f curve
(1.2th power,1.4
th
power,1.6
th
power,1.8
th
power,2th power)
V/f separation
two types:full separation, semi-separation
Jump frequency
adjust from 0.1hz to 500.00hz
Acceleration/deceleration
time
0.00 to 65000 seconds (4-stage acceleration/deceleration time is set
independently), linear or S-curve acceleration/deceleration mode.
Over current stall
prevention level
Can be set according to the motor load characteristics with 100~200% of
the rated current of the driver
DC brake
When stopping, it can be operated from 0.00 to the maximum operating
frequency, and the braking current is 0 to 100% of the rated current;
Start time 0-100.0 seconds, stop time 0-100.0 seconds.
Brake torque
20% (external optional brake resistor can reach 125%)
(1-50HP brake transistor built-in, 60HP and above can be connected to the
external brake unit module)
Speed ratio
open loop vector control:1:100
O
pe
ra
tio
n c
ha
ra
ctr
er
is
tic
Frequency
setting
signal
bit operation
board
set by
external
terminal
0-10VDC
,
4-20mADC
,
Serial communication(RS485)
Operation
signal
bit operation
board
Available to be operated by RUN,STOP,JOG keys
external
terminal
2-wire / 3-wire operation, jog operation, serial communication (RS485)
Input terminal of
multi-function
Forward and reverse running, three-wire operation control, Forward and
reverse jog running, free stop, reset fault, running pause, external fault
input, increment/decrement frequency terminal setting, 16-segment preset
speed switching, acceleration/deceleration time switching , frequency
source switching, running command switching, PID control, PLC status
reset, pause swing frequency, reset swing frequency, prohibit acceleration
and deceleration, disable torque control, calculator function, length count,
frequency increase and decrease setting clear, high speed pulse
frequency , stop DC braking, frequency modification enable, speed control
and torque control switching, clear running time of this time.
Output terminal of
multi-function
Inverter operation, fault output, frequency level detection FDT output,
frequency arrival, zero speed operation, overload pre-alarm, count value
arrival, length arrival, PLC cycle completion, cumulative running time
Содержание S3100A Series
Страница 1: ...S3100Aseries inverter General Open loop Vector Control IM User manual User Manual ...
Страница 23: ...19 Size 3 Unit mm S3100A 2T5 5G 2T7 5G S3100A 4T7 5G 11P 4T18 5G 22P Size 4 Unit mm S3100A 4T22G 30P 4T37G 45P ...
Страница 24: ...20 Size 5 Unit mm S3100A 4T45G 55P 4T110G Size 6 Unit mm S3100A 4T110G 132P 4T160G 185P ...
Страница 25: ...21 Size 7 Unit mm S3100A 4T185G 200P 4T220G Size 8 Unit mm S3100A 4T220G 250P 4T315G ...
Страница 26: ...22 Size 9 Unit mm S3100A 4T315G 355P 4T400G 450P Size 10 Unit mm S3100A 4T450G 500P 4T500G ...