31
3.3 Preliminary Operation-not Connecting With Motor
• Prior to connecting power supply with AC motor drive, check and make sure that AC power supply voltage is
within input voltage range of the drive.
• Connect power supply to R/L1,S/L2 and T/L3 input terminals of the AC motor drive.
• Operation mode control selection.
Operation mode can be divided into the following categories:
□ Both frequency command and operation control are determined by keyboard. (00-00=0) (Factory setting)
IM
□ Frequency command is controlled by keyboard.
Operation command is controlled by external terminals. STOP key on keyboard valid.
Two wire operation control, “FWD/STOP” and “REV/STOP”(04-00=1
,
04-01=2
,
04-09=0 or 1)
IM
DCM
MI2
REV/STOP
FWD/STOP
MI1
□ Frequency command is controlled by keyboard.
Three wire operation control mode Configuration 1 (04-00=1
,
04-01=2
,
04-02=3
,
04-09=2)
IM
DCM
MI1
MI2
FWD/RUN
REV/RUN
MI3
STOP
Содержание S3100A Series
Страница 1: ...S3100Aseries inverter General Open loop Vector Control IM User manual User Manual ...
Страница 23: ...19 Size 3 Unit mm S3100A 2T5 5G 2T7 5G S3100A 4T7 5G 11P 4T18 5G 22P Size 4 Unit mm S3100A 4T22G 30P 4T37G 45P ...
Страница 24: ...20 Size 5 Unit mm S3100A 4T45G 55P 4T110G Size 6 Unit mm S3100A 4T110G 132P 4T160G 185P ...
Страница 25: ...21 Size 7 Unit mm S3100A 4T185G 200P 4T220G Size 8 Unit mm S3100A 4T220G 250P 4T315G ...
Страница 26: ...22 Size 9 Unit mm S3100A 4T315G 355P 4T400G 450P Size 10 Unit mm S3100A 4T450G 500P 4T500G ...