48
SIGNIFICANT INFORMATION
If the orientation is only measured in telescope Face II, the HZ orientation is
based on telescope Face II. If measured only in telescope Face I or mixed the HZ
orientation is based on Face I.
The prism height may not be changed during measurements in the first and
second telescope position.
If a target point is measured several times in the same telescope position, the
last valid measurement is used for the computation.
If no orientation was set and an application was started, and if in “Measure”
All or REC was triggered, then the current HZ direction and V-angle are set as
orientation.
5.4 SURVEYING
The measurement of an unlimited number of points is supported in surveying
program. It is comparable to “
Measure
”, but includes stationing, orientation and
quick coding.
Notice: Set job, station and orientation first.
STEPS
DISPLAY
Press F4 to start
Measure
.
【
Setting Meas.
】
[*]
F1
Setting Job
(1)
[*]
F2
Setting Station
(2)
[*]
F3
Set Orientation
(3)
[
*
]
F4
Start
(4)
F1
F2
F3
F4
Содержание STS-750RC Series
Страница 1: ......
Страница 12: ...11 1 8 MENU TREE Menu F1 F4 Confirms the selected menu Press PAGE to view the next page ...
Страница 152: ......