44
STEPS
DISPLAY
Press F2 to enter to
Setting Station
.
Press SEARCH, or LIST to find an
existed (known) point from internal
memory.
Or press ENH to input the PtID and its
coordinates and save it in the job.
【
Setting Station
】
Input Station PtID!
StnPt
:
OCC1
SEARCH
LIST
ENH
Enter the instrument height, and press
OK to save the station setting.
【
Setting Station
】
Input INS.HT!
INS.Ht
:
2.000m
PtID
OK
5.3 SETTING ORIENTATION
With the orientation, Hz-direction can be input manually or set by points with
known coordinates can be set.
5.3.1 Manually Inputting
STEPS:
1) Press F1 to input a random HZ-orientation.
2) Input Hz-direction, reflector height and PtID.
3) Press All to start measurement and set orientation. Or press RECORD to
record HZ-direction and set orientation.
STEPS
DISPLAY
Press F3 to enter to
Set Orientation
.
Press F1 to set the orientation manually.
【
Orientation
】
F1 Set manually
F2 Known Point
F1
F2
Содержание STS-750RC Series
Страница 1: ......
Страница 12: ...11 1 8 MENU TREE Menu F1 F4 Confirms the selected menu Press PAGE to view the next page ...
Страница 152: ......