2.5 MOUNTING AND DISMOUNTING INSTRUMENT FROM TRIBRACH
Dismounting
If necessary, the instrument (including reflector prisms with the same tribrach)
can be dismounted from tribrach. Loosen the tribrach locking screw in the locking
knob with a screwdriver. Turn the locking knob about 180° counter-clockwise to
disengage anchor jaws, and take off the instrument from the tribrach.
Mounting
Insert three anchor jaws into holes in tribrach and line up the directing stub with
the directing slot. Turn the locking knob about 180°clockwise and tighten the
locking screw with a screw driver.
2.6 EYEPIECE ADJUSTMENT AND COLLIMATING OBJECT
Method of Collimating Object
①
Sight the telescope to bright place and rotate the eyepiece tube until you can
see the reticle clearly.
②
Collimate the target point with top of the triangle mark in the rough collimator.
(Keep a certain distance between eye and the collimator).
③
Make the target image clear with the telescope focusing screw.
If there is parallax when your eye moves up, down or left, right, it means the
diopter of eyepiece lens or focus is not well adjusted and accuracy will be
influenced, so you should adjust the eyepiece tube carefully to eliminate the
parallax.
2.7 INPUTTING MODE
Total Station STS-750RC series has alphanumeric keypad. User therefore can
input numbers and characters directly.
Each key of Total Station STS-750RC series is defined with three characters and
one number.