5
SALICRU
2.1.2. For more information and/or help.
For more information and/or help of your specific unit, request it to
our Service and Technical Support
(S.T.S.)
.
2.2.
SAFETY INSTRUCTIONS.
• Check the data of the nameplate are the required by the installation.
•
Never forget that the
UPS is an electrical energy
generator
, so the
end-user must take all the needed
cautions against direct and indirect contact
.
Its power supply lies in the batteries, a part from AC mains,
which can be included or not in the same case or cabinet of the
electronic parts of the equipment depending on the model and/
or extended autonomies.
When the equipment is ON, if batteries are connected to the equip-
ment and it protections, if any, are turned “On”, the fact that the
UPS is connected or not to mains is irrelevant, as well as the status
of the own protections of mains. The outlets or output terminals
will supply voltage meanwhile there is energy in the battery set.
•
Compliance as regards to “Safety instructions“ is
mandatory, being the user the legal responsible re-
garding
to its observance and application. Read them carefully and
follow the stated steps in the established order, keep them for fu-
ture consults that may arise.
•
If the
instructions are not in total or partial understood
and in special those ones referred to safety, do not
carry
on with the installation or commissioning tasks, because there
could be a
risk on your or on the other/s persons safety
, being
able to make
serious injuries even the death
, also it can cause
damages to the equipment and/or loads and installation
.
•
The local electrical regulations and the different restric-
tions of the client’s site can invalidate some recommen-
dations included in the manuals. When discrepancies exist, the
user has to comply with the local regulations.
•
This equipment must be
installed by qualified per-
sonnel and it can be used by personnel with no
specific training
, just only with the help of this manual.
A person is defined as
qualified
, if he has experience in as-
sembling, commissioning and perfect control operating of the
equipment, if he has the requirements to do the job and if he has
read and understand all the things described in this manual, in
particular the safety indications. Such preparation is considered
valid if it is certified by our
(S.T.S.)
only.
• Warning labels has to be placed in all primary switches, installed in
areas far way from the equipment, in order to warn the electrical
maintenance personnel of the presence of a UPS in the circuit.
The label shall contain the following text or an equivalent one:
Before operating in the circuit.
Isolate the Uninterruptible Power Supply (UPS).
Check the voltage in all terminals, including the earth
main protective earth.
Risk of UPS backfeed voltage.
Never touch or manipulate the components of the elec-
tronic PCB with the hands and without any protection
against electrostatic discharges (ESD). They are highly de-
structive for most of the parts and they can cause expen-
sive breakdown.
«
Main protective earthing terminal
» symbol. Connect the
earth cable coming from the installation to this terminal.
«
Earth bonding terminal
» symbol. Connect the earth
cable coming from the load and the external battery cabinet
to this terminal.
«
Notes of information
» symbol. Additional topics that comple-
ment the basic procedures. These instructions are important for
the equipment use and its optimum efficiency.
It is mandatory the use of insulated gloves to prevent possible
electrical discharges, when manipulating the connections and
especially those related to batteries.
It is mandatory the use of insulated shoe to prevent possible elec-
trical discharges, when manipulating the connections and espe-
cially those related to batteries.
It is mandatory the use of protection glasses, tight and ap-
propriate work clothes, without hanging parts.
Obligation of turning off the equipment power supply or
loads connected at the output.
Read carefully the instruction manual concerning its use.
Smoking, fire or any actions that makes sparks around the
batteries are prohibited.
To pull from connection cables is prohibited. Use the suitable me-
diums to free the connections from terminals.
To touch with bare hands is prohibited. Risk of electric shock
when coming into contact with low potential parts. To
open, manipulate inside the equipment and/or terminals and
battery connections are prohibited for non-authorised and
non-qualified personnel.
To turn randomly the switches or protections is prohibited.
All manoeuvres will be done as it is described in the instruc-
tion manual.
In case the acid of the batteries enters in contact with parts
of the body, wash with plenty of water and go to the nearest
medical service.
Preservation of the environment
: The presence of this
symbol in the product or in their associated documentation
states that, when its useful life is expired, it will not be dis-
posed together with the domestic residuals. In order to avoid
possible damages to the Environment, separate this product
from other residuals and recycle it suitably. The users can con-
tact with their provider or with the pertinent local authorities to
be informed on how and where they can take the product to be
recycled and/or disposed correctly.
Any packaging material must be recycled in accordance
with the legal norms applicable to each country where the
equipment is installed.
Alternating current a.c..