OPERATING INSTRUCTIONS
54
4618 - 021
VIBRATION SETUP
Introduction
This menu is used to set-up the detector for optimum
performance with any vibration present in the system.
NOTE
When adjusting the sensitivity limit ensure that all
mechanical and electronic equipment that may be a
source of vibration is operating (including reject
devices etc.).
Sensitivity limit
This display is used to manually or automatically set-
up the maximum sensitivity that will be set by the
automatic setup feature of the detector. The
maximum sensitivity must be reduced in situations
where the detector is subject to high vibration.
Press the soft key adjacent to sensitivity limit to
manually set the sensitivity limit. Press the ENTER
key when finished.
Press the soft key adjacent to Auto. Adjust to
automatically set the sensitivity limit.
NOTE
Remember to record all settings on the Settings
Sheets at the rear of the manual.
Содержание Signature
Страница 16: ......
Страница 26: ...INSTALLATION 10 4618 021 Fig 5 Typical Metal Detector Conveyor ...
Страница 31: ...INSTALLATION 4618 021 15 Fig 10 Cable Gland Assemblies for Power Supply Unit ...
Страница 52: ...OPERATING INSTRUCTIONS 36 4618 021 Fig 14 Supervisor Mode Flow Chart ...
Страница 55: ...OPERATING INSTRUCTIONS 4618 021 39 Fig 15 Engineer Mode Flow Chart ...
Страница 71: ...OPERATING INSTRUCTIONS 4618 021 55 Fig 16 Pack Sensor Mode Flow Chart ...
Страница 82: ...OPERATING INSTRUCTIONS 66 4618 021 Fig 18 QA Inspector And Operator Flow Chart ...
Страница 92: ...OPERATING INSTRUCTIONS 76 4618 021 Fig 19 Viewing Mode Flow Chart ...