OPERATING INSTRUCTIONS
56
4618 - 021
PACK SENSOR SETUP
Introduction
This facility provides automatic calibration of the pack
sensor if installed.
For connection information and physical
characteristics of the pack sensor input see Technical
Specification and connection details.
Gating
Timers tm2 and tm3 may be gated, however an
external sensor is required to sense the position of the
product/pack when used in the gated mode.
Pack Sensor Fitted
Carry out the following procedure to automatically
calibrate the pack sensor:
YES -
Press the soft key adjacent to YES if a pack
sensor is fitted.
NO -
Press the soft key adjacent to NO if there is no
sensor fitted.
Press the soft key adjacent to ETC to move to the
next display.
Sensor distance
This is the distance between the centre of the pack
sensor and the infeed face of the detector.
Press the soft key adjacent to #####mm to change
the value of sensor distance. This distance should be
entered in mm (inches for U.S. version)
Photogated reject timers provide very precise and
effective reject operations. For example, if a pusher
reject is used to reject boxed product, photogating
ensures that the pusher hits the pack in the same
position every time. Without photogating the rejecting
operation would be dependent upon the position of
the metal contaminant in the pack and hence be more
variable in operation.
NOTE
Remember to record all settings on the Settings
Sheets at the rear of the manual.
U.S. version
Содержание Signature
Страница 16: ......
Страница 26: ...INSTALLATION 10 4618 021 Fig 5 Typical Metal Detector Conveyor ...
Страница 31: ...INSTALLATION 4618 021 15 Fig 10 Cable Gland Assemblies for Power Supply Unit ...
Страница 52: ...OPERATING INSTRUCTIONS 36 4618 021 Fig 14 Supervisor Mode Flow Chart ...
Страница 55: ...OPERATING INSTRUCTIONS 4618 021 39 Fig 15 Engineer Mode Flow Chart ...
Страница 71: ...OPERATING INSTRUCTIONS 4618 021 55 Fig 16 Pack Sensor Mode Flow Chart ...
Страница 82: ...OPERATING INSTRUCTIONS 66 4618 021 Fig 18 QA Inspector And Operator Flow Chart ...
Страница 92: ...OPERATING INSTRUCTIONS 76 4618 021 Fig 19 Viewing Mode Flow Chart ...