OPERATING INSTRUCTIONS
4618 - 021
85
2)
If you only need to select the timer group for
the current product number and not adjust any
of the timer group properties then
a)
Select the soft key adjacent to NO, and go
back to the Engineer Mode section.
!
CAUTION
Although NO was selected the group will be
changed to the group letter selected in 1).
else
b)
Select the soft key adjacent to YES, and
proceed to step 3)
3)
Press the soft key adjacent to tm2[G]
4)
a) If the display opposite appears, press the soft
key adjacent to NO.
else
b)Proceed to step 5)
5) Press the soft key adjacent to SIGNAL DELAY
a)
For packaged or separate products
i)
Place the metal contaminant at the
rear /trailing edge of the product.
ii)
Pass the product with the metal
contaminant attached through the
detector aperture, ensuring that the
product does not slip or skew.
iii)
Use the cursor Up and Down keys to
adjust the Signal Delay so that the
reject device operates as the front
edge of the pack reaches it.
In the following displays ‘X’ represents the timer group A, B or C as
selected at step 1); tmxx represents the timer type that is currently
selected for this timer group.
Содержание Signature
Страница 16: ......
Страница 26: ...INSTALLATION 10 4618 021 Fig 5 Typical Metal Detector Conveyor ...
Страница 31: ...INSTALLATION 4618 021 15 Fig 10 Cable Gland Assemblies for Power Supply Unit ...
Страница 52: ...OPERATING INSTRUCTIONS 36 4618 021 Fig 14 Supervisor Mode Flow Chart ...
Страница 55: ...OPERATING INSTRUCTIONS 4618 021 39 Fig 15 Engineer Mode Flow Chart ...
Страница 71: ...OPERATING INSTRUCTIONS 4618 021 55 Fig 16 Pack Sensor Mode Flow Chart ...
Страница 82: ...OPERATING INSTRUCTIONS 66 4618 021 Fig 18 QA Inspector And Operator Flow Chart ...
Страница 92: ...OPERATING INSTRUCTIONS 76 4618 021 Fig 19 Viewing Mode Flow Chart ...