(Applicable only if ATEX option is ordered)
ATEX DIRECTIVE
•
This product complies with the ATEX Category as stated on the ATEX system label shown below.
•
A static hazard may exist – Do not clean non-metallic parts with a dry cloth.
•
Ensure torque setting on fixings highlighted below conform to the values stated on page 5 “Technical
Specification”.
•
Do not open any electrical enclosures when product is energized or when an explosive dust atmosphere is
present.
•
Regular inspection of plastic and gasket materials should be made to ensure no wear or damage has occurred
that may affect the ingress integrity of the system.
•
The power supply/module enclosure can in some cases accommodate additional glands that can be fitted by
the end user. If new glands or blanking plugs are fitted by the end user they must ensure that the fitting are of
metal construction and that the ingress integrity of the enclosure is maintained. (Must be sealed to IP6X or
better).
Module cover
fixing bolts
Power supply
lid fixing bolts
Module cover
and power
supply lid fixing
bolts
Endplate fixing
bolts torque
4Nm
Position of EX Label
~ See over for more
details
Содержание Signature
Страница 16: ......
Страница 26: ...INSTALLATION 10 4618 021 Fig 5 Typical Metal Detector Conveyor ...
Страница 31: ...INSTALLATION 4618 021 15 Fig 10 Cable Gland Assemblies for Power Supply Unit ...
Страница 52: ...OPERATING INSTRUCTIONS 36 4618 021 Fig 14 Supervisor Mode Flow Chart ...
Страница 55: ...OPERATING INSTRUCTIONS 4618 021 39 Fig 15 Engineer Mode Flow Chart ...
Страница 71: ...OPERATING INSTRUCTIONS 4618 021 55 Fig 16 Pack Sensor Mode Flow Chart ...
Страница 82: ...OPERATING INSTRUCTIONS 66 4618 021 Fig 18 QA Inspector And Operator Flow Chart ...
Страница 92: ...OPERATING INSTRUCTIONS 76 4618 021 Fig 19 Viewing Mode Flow Chart ...