APPENDIX D
4618 - 021
125
Command
1 2
Direction
3
Description
Type
4
‘T’ t ‘,’ n ‘,’ r ‘,’ d
‘,’ p ‘,’ w
‘T?’ t
in/out
in
Timer Settings
6
t = Timer group
t = 0 : timer group A
t = 1 : timer group B
t = 2 : timer group C
n = Timer type
n = 0 : Timer type tm1
n = 1 : Timer type tm2
n = 2 : Timer type tm2G
n = 3 : Timer type tm3
n = 4 : Timer type tm3G
r = Reject time, a five digit number in the range [50..60000].
d = Signal delay, a five digit number in the range [50..60000].
p = Sync delay, a five digit number in the range [50..60000].
w = Window time, a five digit number in the range [50..60000].
Note.
For timer types tm3 and tm3G the titles and range of
acceptable values differ from those shown, refer to the
instruction manual for details.
Note.
The resolution on all timer settings is 2ms.
Timer Settings ?
X
‘U’ y ‘,’ m ‘,’ d
‘U?’
in/out
in
Date
y = The year, a two digit number in the range [0..99].
m = The month, a two digit number in the range [1..12].
d = The day of the month, a two digit number in the range
[1..31]
Date ?
X
‘V’ f ‘,’ n
‘V?’f
in/out
in
Sensitivity limit
f = Frequency offset, a single digit number in the range [0..1].
(Must be 0 for single frequency heads)
n = Sensitivity limit, a three digit number in the range [0...199].
Sensitivity limit
F
‘W’ h ‘,’ m
‘W?’
in/out
in
Time, See Note 2.
h = The hour, a two digit number in the range [0..23]
m = The minute, a two digit number in the range [0..59]
Time ?
X
‘w’ m ‘,’ n’,’ o ‘,’
p
‘w?’
in/out
in
Automatic tracking setup
m : Automatic tracking maximum rate, a five digit, fixed point,
number in the range [1.00...5.00].
n : Automatic tracking maximum span, a four digit, fixed point,
number in the range [3.00...45.00].
o : Automatic tracking damping, a single digit number in the
range [1... 9].
p : Reserved, always zero.
Automatic tracking setup?
F
‘X’ m ‘,’ n
‘X?’ m
in/out
in
Product signal cancellation
m = product number, a two digit number in the range [1..20]
n = 0 : DISABLE
n = 1 : ENABLE
Product signal cancellation (for product number m)?
P
Содержание Signature
Страница 16: ......
Страница 26: ...INSTALLATION 10 4618 021 Fig 5 Typical Metal Detector Conveyor ...
Страница 31: ...INSTALLATION 4618 021 15 Fig 10 Cable Gland Assemblies for Power Supply Unit ...
Страница 52: ...OPERATING INSTRUCTIONS 36 4618 021 Fig 14 Supervisor Mode Flow Chart ...
Страница 55: ...OPERATING INSTRUCTIONS 4618 021 39 Fig 15 Engineer Mode Flow Chart ...
Страница 71: ...OPERATING INSTRUCTIONS 4618 021 55 Fig 16 Pack Sensor Mode Flow Chart ...
Страница 82: ...OPERATING INSTRUCTIONS 66 4618 021 Fig 18 QA Inspector And Operator Flow Chart ...
Страница 92: ...OPERATING INSTRUCTIONS 76 4618 021 Fig 19 Viewing Mode Flow Chart ...