Detector Precautions
!
CAUTION
During installation and operation of the detector the following points must be considered. Failure to do so may result
in difficulties of operation, degradation in the performance or damage occurring to your detector.
1.
Electric Arc Welding
Electric Arc Welding must not be carried out on the detector or on any part of the attached conveyor system.
If Electric Arc Welding must be carried out on any attached systems, disconnect and remove the detector
head and detector power supply box prior to welding.
2.
Power Source
It is recommended that the power source should be taken from a source which supplies only low power
equipment.
It is recommended that the detector should not be connected to power sources which are supplying varying
current loads, e.g. Invertors, variable-speed drives etc.
It is recommended that the power source for the detector should be connected via an independent spur.
The power source for the detector should be fitted with an isolation switch and the appropriate circuit breaker
and/or fuse.
3.
Electromagnetic Interference
It is recommended that the detector should not be installed in close proximity to any devices which may emit
electromagnetic interference e.g. Radio transmitters.
Ensure all Invertors and variable-speed drives in the proximity of the detector are installed in full accordance
with their manufacturers instructions.
Where possible avoid placing any cables from Invertors, variable-speed drives etc. in close proximity to the
detector or the detector cables.
In particular take care to avoid placing the detector in the proximity of any equipment that generates
electromagnetic interference in the same frequency range as the detector.
4.
Magnetic Fields (Ferrous Detectors Only
)
It is recommended that this type of detector should not be installed in close proximity to any potential source of
magnetic fields.
5.
Metal Free Zone (M.F.Z.)
To achieve the optimum detector performance, an area surrounding the aperture of the detector known as the
Metal Free Zone (M.F.Z.) must be kept free of metal.
The size of this zone will be dependant upon the type of detector, the detector’s aperture height and the
detector’s operating sensitivity.
Stationary metal may be positioned closer to the detector than moving metal.
Typical values of M.F.Z for standard metal detectors are:
M.F.Z. = 1.5 x aperture-height for stationary metal
M.F.Z. = 2.0 x aperture-height for moving metal.
Typical values of M.F.Z for Ferrous detectors are:
M.F.Z. = 1.5 x aperture-height for stationary non-Ferrous metal
M.F.Z. = 2.0 x aperture-height for moving non-Ferrous metal.
M.F.Z. = 2.0 x aperture-height for stationary Ferrous metal
M.F.Z. = 3.0 x aperture-height for moving Ferrous metal.
Содержание Signature
Страница 16: ......
Страница 26: ...INSTALLATION 10 4618 021 Fig 5 Typical Metal Detector Conveyor ...
Страница 31: ...INSTALLATION 4618 021 15 Fig 10 Cable Gland Assemblies for Power Supply Unit ...
Страница 52: ...OPERATING INSTRUCTIONS 36 4618 021 Fig 14 Supervisor Mode Flow Chart ...
Страница 55: ...OPERATING INSTRUCTIONS 4618 021 39 Fig 15 Engineer Mode Flow Chart ...
Страница 71: ...OPERATING INSTRUCTIONS 4618 021 55 Fig 16 Pack Sensor Mode Flow Chart ...
Страница 82: ...OPERATING INSTRUCTIONS 66 4618 021 Fig 18 QA Inspector And Operator Flow Chart ...
Страница 92: ...OPERATING INSTRUCTIONS 76 4618 021 Fig 19 Viewing Mode Flow Chart ...