OPERATING INSTRUCTIONS
4618 - 021
37
SUPERVISOR MODE
(Default security code = 0002)
Introduction
Please refer to Figure 14 for the complete sequence
of displays in the Supervisor mode.
The Supervisor mode is intended for personnel who
require to operate the detector in a very limited way
but who are prohibited from altering any settings vital
to the detector operation.
Product Number, Auto Setup and Name
AUTO SETUP
!
CAUTION
Use of the Auto setup facility may alter settings
previously set in other modes.
Press the soft key adjacent to Auto Setup to proceed
to the Auto Setup sub-routine. Refer to the Auto
Setup section for more information.
PROD ##
Press the soft key adjacent to PROD to select the
product number the detector is to use or that you wish
to set up. Use the cursor key and up and down keys
to select a number between 00 and 20. Press the
ENTER key when the correct Product Number is
displayed.
NAME
Press the soft key adjacent to NAME to select the
product by name. Press the ENTER key when the
correct product name is showing.
Sensitivity and Phase
SENS
Press the soft key adjacent to SENS to change the
Sensitivity value. Use the cursor key and up and
down keys to select a value between 000 to 199.
Press the ENTER key when the correct sensitivity is
showing.
Note. At a sensitivity setting of 000 the metal detector
will still be able to detect very large pieces of metal.
PHASE
Press the soft key adjacent to PHASE to change the
phase value.
Use the cursor key and up and down keys to select a
value between 0.00
0
and 180.00
0
.
Press the ENTER key when the correct phase is
showing.
The following items can be set when in the
Supervisors mode.
NOTE
Remember to record all settings on the Settings
Sheets at the rear of the manual.
Содержание Signature
Страница 16: ......
Страница 26: ...INSTALLATION 10 4618 021 Fig 5 Typical Metal Detector Conveyor ...
Страница 31: ...INSTALLATION 4618 021 15 Fig 10 Cable Gland Assemblies for Power Supply Unit ...
Страница 52: ...OPERATING INSTRUCTIONS 36 4618 021 Fig 14 Supervisor Mode Flow Chart ...
Страница 55: ...OPERATING INSTRUCTIONS 4618 021 39 Fig 15 Engineer Mode Flow Chart ...
Страница 71: ...OPERATING INSTRUCTIONS 4618 021 55 Fig 16 Pack Sensor Mode Flow Chart ...
Страница 82: ...OPERATING INSTRUCTIONS 66 4618 021 Fig 18 QA Inspector And Operator Flow Chart ...
Страница 92: ...OPERATING INSTRUCTIONS 76 4618 021 Fig 19 Viewing Mode Flow Chart ...