OPERATING INSTRUCTIONS
102
4618-021
10) Press the soft key adjacent to YES.
11) Ensure that the pack sensor beam is clear of any
packs or products.
12) Select the soft key adjacent to WINDOW SHIFT.
The display should show ‘-RUN-’.
13) Pass the product sample through the pack
sensor beam, ensuring that it does not skew or
slip on the conveyor.
The metal detector will automatically measure
the window shift and display this instead of the -
RUN
- message.
14) Repeat steps 12) and 13) to ensure that the
window shift is being measured correctly and is
repeatedly calculating the same value, (within
±
10%).
15) Ensure that the pack sensor beam is clear of any
packs or products.