92
Input/output patchbay
Input/output patchbay
The input patchbay library lets you store the current input patchbay
settings for later recall.
The INPUT PATCHBAY LIBRARY popup is used to perform input
patchbay library operations.
1.
Access the PATCHBAY screen.
fig.ScrPatchIn1608.eps
2.
Press [F1 (INPUT)] to access the INPUT tab.
3.
Press [F6 (LIBRARY)] to access the INPUT PATCHBAY
LIBRARY popup.
fig.ScrInPatLibGuide.eps
A.
Library data list
This lists the library data.
The function buttons perform the following operations.
* Available only for the User library.
For details on library operations, refer to “Library operations”
(p. 39).
1.
Access the PATCHBAY screen.
ig.ScrPatchIn1608.eps
2.
Press [F2 (OUTPUT)] to access the OUTPUT tab.
fig.ScrPatchOut1608.eps
3.
Press [F3 (REAC A)], [F4 (REAC B)], or [F5 (CONSOLE)] to
select the desired location for the output jack.
4.
Move the cursor to the intersection of the desired channel
and jack, and press [ENTER].
fig.ScrPatchOutChgConf.eps
If a channel is already patched to the output port, a message
will ask you to confirm the output patching change.
Press [F8 (ASSIGN)] to change the output patching.
If you press [F7 (CANCEL)] the output patching change will be
cancelled.
If the “PATCHBAY CHANGE” item in the CONFIRMATION
section of User Preference (p. 155) is unselected, no
confirmation message will appear in step 4.
Using the input patchbay library
[F1 (PRESET)]
Displays the recall-only PRESET li-
brary.
[F2 (USER)]
Displays the USER library, which lets
you recall or store data.
[F4 (RECALL)]
Recalls the library data that is selected
in the list.
[F5 (STORE)]*
Stores settings to the library data that
is selected in the list.
[F6 (LOCK)]*
Locks the library data that is selected
in the list.
[F7 (NAME EDIT)]*
Accesses the NAME EDIT popup for
editing the name of the user library
data that is selected in the list.
[F8 (CLOSE)]
Closes the popup.
A
Output patchbay operations
Editing the output patching
M-380_e1.book 92 ページ 2010年6月30日 水曜日 午前10時31分