A4
US
US
A4
US
A4
US
A4
12
wARnIng:
enCLosuRe MATeRIALs
CMA actuator castings are manufactured from aluminium
alloy with stainless steel fasteners. The user must ensure that
the operating environment and any materials surrounding the
actuator cannot lead to a reduction in the safe use of, or the
protection afforded by the actuator. Where appropriate the
user must ensure the actuator is suitably protected against its
operating environment.
hAndwheeL opeRATIon
The handwheel is located on
the top cover of the CMA (All
Variants). Push and hold the
hand wheel down and rotate
to extend/retract or rotate the
actuator output drive.
verify direction of output shaft rotation for clockwise
operation of the handwheel. (varies with frame size).
wARnIng:
opeRATIng by hAnd
note that under no circumstances should any
additional lever device such as a wheel key or wrench
be applied to the hand-wheel in order to develop more
force when closing or opening the valve as this may
cause damage to the valve and/or actuator. It may also
cause the valve to become stuck in the seated or back
seated position.
Installation & setup
Model
output when hand Knob
is Turned Clockwise
CMA - Linear
Extend or Retract
CML-100/250
Retract
CML-750
Extend
CMA - Quarter-turn
CMQ-250
Anticlockwise
CMQ-500
Anticlockwise
CMQ-1000
Anticlockwise
CMA -Rotary
CMR-50
Clockwise
CMR-100
Clockwise
CMR-125
Clockwise
CMR-200
Clockwise
CMR-250
Clockwise
InsTALLIng youR ACTuAToR
The following instructions must be followed and integrated
into your safety program when installing and using Rotork
products.
•
Read and save all instructions prior to installing,
operating and servicing this product.
•
If you don’t understand any of the instructions contact
Rotork for clarification.
•
Follow all warnings, cautions and instructions marked on
and supplied with the product.
•
Inform and educate personnel in the proper installation,
operation and maintenance of the product.
Install equipment as specified in Rotork installation
instructions and as per applicable local and national
codes of practice. Connect all products to the proper
electrical sources.
•
To ensure proper performance, use only qualified
personnel to install, operate, update and maintain
the unit.
•
When replacement parts are required, ensure that the
qualified service technician uses only replacement parts
specified by Rotork.
•
Substitutions will invalidate any hazardous area
certification and may result in fire, electrical shock, other
hazards or improper operation.
•
Keep all product protective covers in place (except during
installation or maintenance by qualified personnel)
to prevent electrical shock, personal injury or damage
to equipment.
•
Operation of the actuator in an inappropriate fashion
may cause harm or damage to the unit or surrounding
equipment.
The end user should take care when assessing the local
ambient temperature to take into account the heat from any
connecting pipe-work or inherent heat from process plant etc.
wARnIng
Before installing the actuator, make sure that it is suitable for
the intended application. If you are unsure of the suitability
of this equipment for your installation consult Rotork prior to
installation.
wARnIng:
eLeCTRIC shoCK hAZARd
Installation and servicing must be performed only by
qualified personnel.
wARnIng:
eLeCTRosTATIC dIsChARge
This equipment houses static sensitive devices. To protect the
internal components never touch the printed circuit boards
without using electrostatic (ESD) control procedures.
Fig. 12.1