Redefining Flow Control
The CMA Actuator is available for Linear, Quarter-turn or
Rotary valves, dampers or other devices.
Each of these applications may require different methods of
mounting the actuator to the valve.
Typical examples only are described in this publication and do
not cover all possible variants of valve types.
CML - LIneAR unIT - MounTIng
CAuTIon
It is essential that the actuator mounting procedure is
carried out when the valve is not under working process
conditions, as full valve movement may occur.
IMpoRTAnT
It is essential that the actuator is mounted correctly to
the valve.
The height of the yoke or pillar and mounting plate, in
relation to the top of the valve spindle is critical to ensure full
stroke movement of the valve.
The Installation & Setup will include the following procedures:
1. Ensure Valve is closed and safe (Offline).
2. Actuator output shaft is retracted.
3. Mount and align actuator to valve.
4. Carry out Basic Setup
Mounting the Actuator
CML-750
CML-100 & CML-250