![Rosemount 3095FB Скачать руководство пользователя страница 102](http://html.mh-extra.com/html/rosemount/3095fb/3095fb_reference-manual_1487388102.webp)
Model 3095FB Multivariable Transmitter with Modbus Protocol
Modbus Protocol Guide
Page 71 of 79
0119-
0124
Input reg-
ister
RO
Diagnos-
tics
Status Bytes(U16)
0125
Holding
register
R/W, WP
PV Scaled
Integers
Maximum Integer
0126
Holding
register
R/W, WP
LCD
LCD Update Rate
0127,
0128
Holding
register
R/W, WP
LCD Display Bit Mask
0129,
0130
Input reg-
ister
RO
Reserved
0131
Holding
register
R/W, WP
Communi-
cations
Options
Turnaround Delay Time
0132
Holding
register
R/W, WP
Floating Point Format Code
0132-
0144
Holding
register
R/W
Reserved
0145
Input reg-
ister
RO
Communi-
cation Sta-
tistics
Framing Error Count
0146
Input reg-
ister
RO
Noise Error Count
0147
Input reg-
ister
RO
Overrun Error Count
0148
Input reg-
ister
RO
CRC Error Count
0149
Input reg-
ister
RO
Busy Count
0150
Input reg-
ister
RO
Good Message Count
Input and Holding Registers (includes Floating Point and ASCII registers)
Modbus Access
DESCRIPTION
Address
Address
Type
Attributes
Functional
Area
Data / Control