Reference Manual
00809-0100-4738, Rev DA
May 2006
Rosemount 3095FB
2-2
GENERAL
CONSIDERATIONS
Measurement accuracy depends upon proper installation of the transmitter
and impulse piping. Mount the transmitter close to the process and use
minimal impulse piping to achieve best accuracy. Keep in mind the need for
easy access, personnel safety, practical field calibration, and a suitable
transmitter environment. Install the transmitter to minimize vibration, shock,
and temperature fluctuation.
IMPORTANT
Install the enclosed pipe plug in unused conduit openings with a minimum of
five threads engaged to comply with Explosion-Proof requirements. The
transmitter is shipped with the plug installed on transmitters ordered with CSA
Explosion-Proof approval.
MECHANICAL
CONSIDERATIONS
“Dimensional Drawings” beginning on page A-5 show dimensional drawings.
Figure 2-4 on page 2-9 shows installation examples.
NOTE
For steam service or for applications with process temperatures greater than
the limits of the transmitter, do not blow down impulse piping through the
transmitter. Flush lines with the blocking valves closed and refill lines with
water before resuming measurement.
NOTE
When the transmitter is mounted on its side, position the Coplanar flange to
ensure proper venting or draining. Mount the flange as shown in Figure 2-4 on
page 2-9, keeping drain/vent connections on the bottom for gas service and
on the top for liquid service.
ENVIRONMENTAL
CONSIDERATIONS
The following guidelines can help optimize transmitter performance. Mount
the transmitter to minimize ambient temperature changes, vibration,
mechanical shock, and external contact with corrosive materials. Appendix A:
Range and Sensor Limits on page A-1 lists the transmitter temperature
operating limits.
Improper assembly of manifolds to traditional housing can damage sensor module.
•
For safe assembly of manifold to traditional flange, bolts must break back plane of
flange web (i.e. bolt hold) but must not contact module housing.