Technical data
Version 1
UPT-6006
Page 55
10
Technical data
Operation of the temperature controller outside of these technical specifications results in loss of
warranty and can cause defects.
Design
Housing for electrical cabinet mounting
On TS35 top hat rail (35mm) in accordance with DIN EN 50022 latchable
Basic surface: 90x75 mm; depth: 135 mm (incl. connection terminals)
Network voltage
Connected between neutral conductor and an outside conductor:
110 VAC -15%…300 VAC +10%
or
Connected between two outside conductors:
110 VAC -15%…415 VAC +10%
The voltage between outside conductor and earth must not exceed
300 VAC.
Power supply net-
work
Symmetrical TN or TT network with max. 415 VAC
Overvoltage category III
Operation in voltage-free network (e.g. IT network) only after checking
with ROPEX.
Network frequency
47…63 Hz, automatic frequency adjustment in this range
Current consumption
(Primary current of the
impulse
transformer)
I
max
= 5 A (ED = 100%)
I
max
= 25 A (ED = 20%, duration of play 1 min)
24 VDC power supply
Terminal 5+7 or
PROFIBUS plug, pin
2+7
24 VDC, Imax = 100 mA
Tolerance: ±10%
SELV or PELV supplied from maximum 300 VAC, Cat II
The 24 VDC power supply can be supplied via terminal 5 and 7 or via the
PROFIBUS plug at pin 2 and 7.
Measurement range
Secondary voltage U
R
:
0.4…120 VAC
Secondary current I
R
:
30…500 A (with transformer PEX-W4/-W5)
ROPEX application report
PROFIBUS DP inter-
face
Baud rates:
9.6 kbit/s; 19.2 kbit/s; 45.45 kbit/s; 93.75 kbit/s; 187.5 kbit/s;
500 kbit/s; 1.5 kbit/s; 3 kbit/s; 6 kbit/s; 12 kbit/s
I/O data length:
Up to 4 bytes of input data
Up to 8 bytes of output data
Freeze mode, sync mode, clear mode, auto baud, configurable device parame-
ters, data byte swapping, PROFIBUS address over rotary coding switch 1…99 or
over set salve address 0…126
Correction plug according to IEC 61158
!
!
!