Device functions
Version 1
UPT-6006
Page 19
It is functioning correctly when the temperature (i.e. signal change at the analogue output or the actual value
in the PROFIBUS protocol) is steady, that is, does not jump, oscillate or even go briefly in the wrong direction.
Such action indicates an incorrect placement of the U
R
measurement line.
When an error message is issued, proceed according to section 8.19 "Error messages" on page 49.
11.The heatup process and the temperature control must be optimized by means of setting the correction factor
Co in the PROFIBUS parameter data (GSD file) or in the DPV1 protocol extension (
section 8.7.10 "Correc-
tion factor Co" on page 34) now. With this setting the manufacturing process related tolerances of the heating
element are compensated.
8
Device functions
See also section 6.6 "Connection diagram (standard)" on page 13.
8.1
Display and operating elements
(yellow LED)
OUTPUT
HEAT
(green LED)
AUTOCAL
ALARM
(yellow LED)
(red LED)
Indicates pulses in
measurement mode. In control
mode, luminous intensity is
proportional to heating current.
Lit while AUTOCAL process is
executing.
Lit or blinking to indicate fault.
Lit during heating phase.
BUS FAILURE
(red/green
LED)
DATA EXCH
(red/green
LED)
(green
)
LED
BUS POWER
(green
)
LED
24 V POWER
Lit or blinking if no connection
exists to PROFINET.
Lit if internal power supply for
PROFINET interface is OK.
Lit (green) while data exchange
with PROFINET controller.
Lit if external 24 VDC power
supply is present.
12 13 14 15 16 17 18
9
8
6
5
10 11
7
4
3
2
1
Vi s u a l
!
AC
HEAT
OUTPUT
ALARM
BUS FAILURE
DATA EXCHANGE
BUS POWER
24 V POWER
www.
.de
ROPEX
Made in Germany
PROFIBUS
UPT-6006