Device functions
Page 42
UPT-6006
Version 1
When writing the date or time, a plausibility check that takes leap years into account is performed. If the transferred
values do not contain valid date or time information, the UPT-6006 answers with an access error 0xb7 “invalid
range”. To avoid inconsistencies, individual values for the date or time should be changed together with write
access, that is, index 100…103 or 104…106.
Slot 1, index 180 contains the start temperature (
section 8.6.13 "Start temperature" on page 30) and index 182
the internal device temperature. These values can only be read and not written.
Slot
Index
Parameter
Range of values
1
100/101
Time: Milliseconds (only whole sec-
onds)
1
1. Milliseconds are not supported by the internal real time clock; read access always delivers whole multi-
ples of 1000. When writing, parts of 1000 are ignored.
0…59000
1
102
Time: Minutes
0…59
1
103
Time: Hours
0…23
1
104
Date: Days (day of the week not sup-
ported in the upper 3 bits)
1…31
1
105
Date: Month
1…12
1
106
Date: Year
0…99
1
107…110
Operating hours [0.1 h]
0…999999999
(0…99999999.9 h)
1
111…114
Not-resettable total cycles counter
0…999999999
1
115…118
Resettable total cycles counter
0…999999999
1
119…122
Cycle counter, channel 0
0…999999999
1
123…126
Cycle counter, channel 1
0…999999999
1
127…130
Cycle counter, channel 2
0…999999999
1
131…134
Cycle counter, channel 3
0…999999999
1
135…138
Cycle counter, channel 4
0…999999999
1
139…142
Cycle counter, channel 5
0…999999999
1
143…146
Cycle counter, channel 6
0…999999999
1
147…150
Cycle counter, channel 7
0…999999999
Slot
Index
Parameter
Range of values
1
180/181
Start temperature
-99…500 °C
1
182/183
Device temperature
-60…190 °C