Device functions
Version 1
UPT-6006
Page 47
8.13
AUX interface
Internal interface for diagnosis and maintenance. The interface is currently not available.
8.14
Total cycles counter
The number of sealing cycles performed (ST bit = 1) since delivery is stored in the controller. This counter can only
be displayed. Resetting of the counter is not possible. Display is possible with the ROPEX visualisation software
(
section 8.12 "USB interface for visualisation software ROPEXvisual
®
" on page 46) or over the acyclical ser-
vices of the PROFIBUS interface.
8.15
Operating hours counter
The operating hours since delivery are stored in the controller. This counter works with an accuracy of 6 minutes
and can only be displayed. Resetting of the counter is not possible. Display is possible with the ROPEX visualis-
ation software (
section 8.12 "USB interface for visualisation software ROPEXvisual
®
" on page 46) or over the
acyclical services of the PROFIBUS interface.
8.16
Data storage for error messages and AUTOCAL
To make error diagnosis easier in ongoing operation, the controller UPT-6006 has data storage for error messages
(
section 8.19 "Error messages" on page 49) and executed AUTOCAL procedures (
section 8.5.2 "AUTOCAL
autom. zeroing (AC)" on page 25).
The last 400 messages are stored. These can be read out and displayed with the ROPEX visualisation software
(
section 8.12 "USB interface for visualisation software ROPEXvisual
®
" on page 46) or through the integrated
Web server.
The UPT-6006 also has an integrated clock (
section 8.17 "Integrated clock (date and time)" on page 47). The
messages are then stored with the date and time specified (time stamp).
The stored messages can be exported as a csv-file. If needed, ROPEX can evaluate the exported file
and create an error diagnosis.
8.17
Integrated clock (date and time)
The UPT-6006 has an integrated clock. The messages are stored in data storage (
section 8.16 "Data storage
for error messages and AUTOCAL" on page 47) with the date and time specified (time stamp). This permits a more
precise identification of error messages, such as when problems have to be analysed.
0
5
1 2
34
6
7
8 9
AUX
CONF
IG
URAT
IO
N
ALA
RM
OUT
PU
T
ENER
GIZ
ED
(
)
A T
ALARM
-
DEE
NE
RG
IZ
ED
!
Содержание CIRUS UPT-6006
Страница 62: ...Index Page 62 UPT 6006 Version 1 ...