Device functions
Page 32
UPT-6006
Version 1
27
Hold mode
Off
Off,
On,
2 sec.
28
Calibration temperature, channel 1
20 °C
-1, 0…40 °C
29
Correction factor, channel 1
100%
25…200%
30/31
Temperature coefficient, channel 1
1700 ppm/K
400…4000 ppm/K
32
Calibration temperature, channel 2
20 °C
-1, 0…40 °C
33
Correction factor, channel 2
100%
25…200%
34/35
Temperature coefficient, channel 2
1700 ppm/K
400…4000 ppm/K
36
Calibration temperature, channel 3
20 °C
-1, 0…40 °C
37
Correction factor, channel 3
100%
25…200%
38/39
Temperature coefficient, channel 3
1700 ppm/K
400…4000 ppm/K
40
Calibration temperature, channel 4
20 °C
-1, 0…40 °C
41
Correction factor, channel4
100%
25…200%
42/43
Temperature coefficient, channel 4
1700 ppm/K
400…4000 ppm/K
44
Calibration temperature, channel 5
20 °C
-1, 0…40 °C
45
Correction factor, channel5
100%
25…200%
46/47
Temperature coefficient, channel 5
1700 ppm/K
400…4000 ppm/K
48
Calibration temperature, channel 6
20 °C
-1, 0…40 °C
49
Correction factor, channel 6
100%
25…200%
50/51
Temperature coefficient, channel 6
1700 ppm/K
400…4000 ppm/K
52
Calibration temperature, channel 7
20 °C
-1, 0…40 °C
53
Correction factor, channel 7
100%
25…200%
54/55
Temperature coefficient, channel 7
1700 ppm/K
400…4000 ppm/K
1. The standard value is stored in the GSD file and is transmitted at system start from the
PROFIBUSmaster to the UPT-6006.
No.
Function
Standard value
1
Possible values
Содержание CIRUS UPT-6006