Device functions
Version 1
UPT-6006
Page 25
The 4x16 bit
output data
contain the actual value in the word
, the status information in the word
, the error
number in the word
, and the start temperature in the word
:
8.5
Input data
Input data are the data transmitted from the PROFIBUS master to the UPT-6006. They contain the setpoint value
and control functions, such as START or AUTOCAL for the UPT-6006. The functions are explained in the fol-
lowing.
8.5.1
Clear mode
If the PROFIBUS master does not send any data, all bits in the device are set to 0 (inactive). An active sealing
procedure will be interrupted by this.
8.5.2
AUTOCAL autom. zeroing (AC)
Due to automatic zeroing (AUTOCAL), manual zero point setting at the controller is not necessary. With the
AUTOCAL function, the controller adapts to the current and voltage signals present in the system and adjusts to
the value predefined in the parameter data (
section 8.7.4 "Variable calibration temperature" on page 33). If no
parameter data are transmitted from the PROFIBUS master, the standard value is 20 °C.
With some PROFIBUS masters, the parameter data cannot be changed during operation. Adjustment of the cali-
bration data to the current ambient conditions in the machines is therefore not possible.
The calibration temperature – with the appropriate setting in the parameter data (
section 8.7.4 "Variable cali-
bration temperature" on page 33) – can therefore be specified at every zeroing through the input data “Setpoint/
AC temperature”. This can be done in the range 0…+40 °C. The specified value for the calibration temperature
Reserve
Channel
Reserve
Control function
Name:
0
0
0
0
0
CH2
CH1
CH0
0
0
0
MA
MP
RS
ST
AC
Bit no.:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Actual value (with prefix)
Name:
Bit no.:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Reserve
Channel
Status information
Name:
0
0
0
MU
CH2
CH1
CH0
SA
IA
WA
AA
AG
AL
TE
TO
RA
Bit no.:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Error number
Name:
0
0
0
0
0
0
A9
A8
A7
A6
A5
A4
A3
A2
A1
A0
Bit no.:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Start temperature (with prefix)
Name:
Bit no.:
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Содержание CIRUS UPT-6006