Manual
Double Sheet Detector R1000 series E20
with integrated fieldbus interface
Communication with the PLC
B0046191 / Rev. 1.12
78
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Bytes 15 - 17:
Byte.Bit
PLC -> R1000 (BIN)
R1000 -> PLC (BOUT)
15.0
---
Type of material at sensor 2 (here always 1)
15.1
---
Current measuring program S2: Teach-In performed
15.2
Zero adjust (sensor 2)
---
15.3
Teach-In 1-sheet (sensor 2)
---
15.4
---
Warning
2)
15.5
---
0-sheet
2)
sensor 2
15.6
---
1-sheet
2)
sensor 2
15.7
---
2-sheet
2)
sensor 2
16.0
---
High byte thickness value
4)
(sensor 2)
16.1
---
16.2
---
16.3
---
16.4
---
16.5
---
16.6
---
---
16.7
---
---
17.0
---
Low byte thickness value
4)
(sensor 2)
17.1
---
17.2
---
17.3
---
17.4
---
17.5
---
17.6
---
17.7
---
1), 2), 3), 4)
Footnotes see Table “Bytes 21 to 23”