Electrical installation
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
67
5.2.5.8 CC-Link
The unit supports the protocol version 1 of CC-Link.
An M12 plug with A-coding is used for the CC-Link connection. A T-connector is not necessary,
because the control unit is equipped with input and output.
The corresponding cable plugs are part of the standard scope of supply.
5.2.5.9 EtherNet/IP
The EthernetI/P connection is implemented as 1-Port.
Round-shape connector, M12, 4-pin., D-coded,
socket contact at control unit (Pos. C2)
View:
Plug side
Pin 1
TD +
Pin 2
RD +
Pin 3
TD –
Pin 4
RD –
Plug enclosure
Shield
The corresponding cable plugs are part of the standard scope of supply.
1
2
3
4
Note
If the E20 is the last participant in the bus, then an external
termination resistor should be placed into the open connector. The
resistor is not included in the scope of supply. A resistor between
DA und DB 110 Ohm or 130 Ohm ½ Watt can be used.
Allocation of CC-Link connection
Input (Pos. B)
Output (Pos. C)
M12, 4-pin, A-coded, male connector at control unit
M12, 5-pin, A-coded, female connector at control unit
2
1
3
4
View:plug side
Pin 1
SLD
View:plug side
Pin 2
DB
Pin 3
DG
Pin 4
DA
Pin 5
---
Suppliers / types / notes: Binder, type 715 (A-coded) and others
1
2
5
4
3