Bytes 12 - 14:
Byte.Bit
PLC –> R1000 (BIN)
R1000 –> PLC (BOUT)
12.0
---
Type of material at sensor 1 (here always 1)
12.1
---
Current measuring program S1: Teach-In performed
12.2
Zero adjust (sensor 1)
---
12.3
Teach-In 1-sheet (sensor 1)
---
12.4 ---
Warning
2)
12.5 ---
0-sheet
2)
sensor 1
12.6 ---
1-sheet
2)
sensor 1
12.7 ---
2-sheet
2)
sensor 1
13.0
---
High byte thickness value
4)
(sensor 1)
13.1 ---
13.2 ---
13.3 ---
13.4 ---
13.5 ---
13.6 ---
---
13.7 ---
---
14.0
---
Low byte thickness value
4)
(sensor 1)
14.1 ---
14.2 ---
14.3 ---
14.4 ---
14.5 ---
14.6 ---
14.7 ---
2), 4)
Footnotes see Table “Bytes 21 to 23”